Specifications

Table Of Contents
Cinterion
®
TX62-W/TX82-W Hardware Interface Description
3.2 Power Up/Power Down Scenarios
120
t TX62-W_TX62-W-x_TX82-W-x_HID_v01.200d 2022-09-08
Public / Preliminary
Page 84 of 170
A low level of the V180 signal - in addition to the regular "^SHUTDOWN" URC issued by the
module - indicates that the switch off procedure has completed and the module has entered
the Power Down mode.
Note: Using the command AT^SMSO=”fast”, it is possible to trigger a fast shutdown procedure,
i.e., shutting down without gracefully deregistering from the network thus saving time between
T0 - T2. Same as with the fast shutdown procedure triggered with the FST_SHDN line (see
Section 2.1.11.3), there will be no ^SHUTDOWN URC in this case. The timings for module
switch off using AT^SMSO=”fast” are listed below in Table 20.
Table 19: Switch off timing values (AT^SMSO)
Timing Description Typical value Unit
TX62-W
T0 - T1 AT^SMSO – URC 294.13
1
(depending on
network)
ms
T1 - T2 URC – V180 13.68
T2 - T3 V180 – V180 (low) 0.83
T3 - T4 V180 (low) – VCORE 2.41
TX62-W-B
T0 - T1 AT^SMSO – URC 302.63
1
(depending on
network)
ms
T1 - T2 URC – V180 13.70
T2 - T3 V180 – V180 (low) 0.70
T3 - T4 V180 (low) – VCORE 2.50
TX62-W-C
T0 - T1 AT^SMSO – URC 234.92
1
(depending on
network)
1. Value is dependent on network, and may take up to 5 seconds for LTE Cat NB1/2 networks.
ms
T1 - T2 URC – V180 37.17
T2 - T3 V180 – V180 (low) 0.65
T3 - T4 V180 (low) – VCORE 2.53
TX82-W
T0 - T1 AT^SMSO – URC 294.13
1
(depending on
network)
ms
T1 - T2 URC – V180 13.68
T2 - T3 V180 – V180 (low) 0.83
T3 - T4 V180 (low) – VCORE 2.41
TX82-W-B
T0 - T1 AT^SMSO – URC TBD. ms
T1 - T2 URC – V180 TBD.
T2 - T3 V180 – V180 (low) TBD.
T3 - T4 V180 (low) – VCORE TBD.