Specifications
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.2 RF Antenna Interface
- 2.3 GNSS Interface
- 2.4 Sample Application
- 3 Operating Characteristics
- 3.1 Operating Modes
- 3.2 Power Up/Power Down Scenarios
- 3.3 Power Saving
- 3.4 Power Supply
- 3.5 Operating Temperatures
- 3.6 Electrostatic Discharge
- 3.7 Blocking against RF on Interface Lines
- 3.8 Reliability Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 4.1 Mechanical Dimensions of TX62-W
- 4.2 Mechanical Dimensions of TX82-W, TX82-W-B, TX62-W-B and TX62-W-C
- 4.3 Mounting TX62/TX82 onto the Application Platform
- 4.4 Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
TX62-W/TX82-W Hardware Interface Description
3.2 Power Up/Power Down Scenarios
120
t TX62-W_TX62-W-x_TX82-W-x_HID_v01.200d 2022-09-08
Public / Preliminary
Page 85 of 170
Table 20: Switch off timing values (AT^SMSO=”fast”)
Timing Description Typical value Unit
TX62-W
T0 - T1 AT^SMSO=”fast” – URC 3.34 ms
T1 - T2 URC – V180 1.51
T2 - T3 V180 – V180 (low) 0.83
T3 - T4 V180 (low) – VCORE 2.39
TX62-W-B
T0 - T1 AT^SMSO=”fast” – URC 3.48 ms
T1 - T2 URC – V180 8.87
T2 - T3 V180 – V180 (low) 0.67
T3 - T4 V180 (low) – VCORE 2.53
TX62-W-C
T0 - T1 AT^SMSO=”fast” – URC 4.62 ms
T1 - T2 URC – V180 12.28
T2 - T3 V180 – V180 (low) 0.59
T3 - T4 V180 (low) – VCORE 2.62
TX82-W
T0 - T1 AT^SMSO=”fast” – URC 3.34 ms
T1 - T2 URC – V180 1.51
T2 - T3 V180 – V180 (low) 0.83
T3 - T4 V180 (low) – VCORE 2.39
TX82-W-B
T0 - T1 AT^SMSO=”fast” – URC TBD. ms
T1 - T2 URC – V180 TBD.
T2 - T3 V180 – V180 (low) TBD.
T3 - T4 V180 (low) – VCORE TBD.