DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality.
Copyright © 2005~ 2008 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice.
RELEASE NOTES VERSION DATE NOTES 2.21 Jan. 02, 2008 Larger setup barcodes 2.20 Nov. 30, 2007 New Word template applied 2.15 Nov.13, 2006 2.14~ Nov. 06, 2006 New: Bluetooth HID supports Japanese keyboard. 2.12 Mar. 03, 2006 2.11 Jan.27, 2006 Modified: Typo errors corrected. 2.10 Jan.18, 2006 Modified: Bluetooth HID doesn’t support the following functions on New: 3667 Bluetooth Cradle for 1166/1266 Modified: Auto-Sense mode supported on 1100 only.
CONTENTS RELEASE NOTES .................................................................................................................................. 3 OVERVIEW............................................................................................................................................ 1 Enter Configuration Mode................................................................................................................. 1 Exit Configuration Mode..........................................
Scanner Configuration SmartScan Manual 3.1.7 Digits Transmission..........................................................................................................15 3.1.8 ALT Composing................................................................................................................. 15 3.1.9 Inter-Character Delay .......................................................................................................15 3.1.10 Laptop Support ...............................................
Scanner Configuration SmartScan Manual 5.3 Code ID Setting ......................................................................................................................... 43 5.3.1 Clear Code ID Settings .....................................................................................................43 5.3.2 Select Pre-defined Code ID..............................................................................................44 5.3.3 Change Code ID..............................................
OVERVIEW ENTER CONFIGURATION MODE Serial Command N/A Enter Setup EXIT CONFIGURATION MODE UPDATE SETTINGS Serial Command 9999 Update EXIT WITHOUT CHANGES Serial Command 9998 Abort RESTORE DEFAULTS Serial Command 9993 Restore Defaults Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”.
Scanner Configuration SmartScan Manual LIST CURRENT SETTINGS Serial Command 9950 List settings regarding Interface, Buzzer, and Scanner Parameters Page 1 Serial Command 9951 List settings regarding Prefix, Postfix, and Length Code Setting Page 2 Serial Command 9952 List settings regarding Code ID Page 3 Serial Command 9953 List settings regarding: Readable Symbologies Page 4 Serial Command 9954 List settings regarding Symbology Parameters (1/3) Page 5 Serial Command 9955 List settings regarding
Chapter 1 BLUETOOTH SETTINGS (1166/1266) 1.1 RF AUTO SHUTDOWN (SUSPEND MODE) 1) Read this label to specify the time interval before the scanner enters suspend mode. 2) Read the “Decimal Value” label on page 57. For example, read “1” and “5” for the scanner to suspend the connection with 3666 after being idle for 15 minutes. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0445 RF Auto Shutdown after … minutes 1.
Scanner Configuration SmartScan Manual 1.4.2 SEND DATA Serial Command 9918 Send Data 1.4.3 CLEAR DATA 1) Read the “Clear Data” label to clear the flash memory. 2) Read the “Confirm” label to confirm the action. Serial Command 9916 Serial Command 9917 Clear Data Confirm 1.4.
Chapter 1 Bluetooth Settings (1166/1266) 1.5 SET CONNECTION WITH 3666 1) Read this label or the same one at the bottom of the 3666 cradle. 2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds. 3) Proceed to select a desired output interface. Serial Command Set Connection 1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE 1.6.
Scanner Configuration SmartScan Manual 1.6.2 BLUETOOTH HID PARAMETERS 1) Read this label to activate Bluetooth HID and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0000 Activate & Select Keyboard Type … NO. KEYBOARD TYPE NO.
Chapter 1 Bluetooth Settings (1166/1266) PIN CODE 1) Read this label to specify the PIN code. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string (max. 6 characters are allowed). 3) Read the “Validate” label on the same page to complete this setting.
Scanner Configuration SmartScan Manual CAPITAL LOCK SETTING Serial Command 0003 Serial Command 0002 Auto Detection Capital Lock ON Serial Command 0004 ALPHABETS TRANSMISSION Serial Command 0006 Serial Command 0005 Ignore Case DIGITS TRANSMISSION Serial Command 0014 Serial Command 0013 Numeric Key ALT COMPOSING Serial Command 0334 Serial Command 0335 Yes 8 Enter Setup
Chapter 2 READER SETTINGS 2.1 GOOD READ NOTIFICATION 2.1.1 BUZZER SETTING Serial Command 0319 Serial Command 0318 Disable Buzzer 2.1.2 BUZZER FREQUENCY Serial Command 0047 Serial Command 0046 8 kHz <4 kHz> Serial Command 0049 Serial Command 0048 2 kHz 1 kHz 2.2 READ REDUNDANCY Serial Command 0202 Serial Command 0201 Serial Command 0203 One Time Serial Command 0204 Two Times Three Times 2.
Scanner Configuration SmartScan Manual Serial Command 0069 Serial Command 0068 Auto Power Off Mode Serial Command 0070 Alternate Mode Serial Command 0071 Momentary Mode Repeat Mode Serial Command 0073 Serial Command 0072 Test Mode (Default for 1100/1105/1166/1200/1266) 2.4 AUTO-SENSE MODE (1100 ONLY) Serial Command 0333 Serial Command 0332 Enable 2.
Chapter 2 Reader Settings Serial Command 0339 Serial Command 0338 <400 ms> 800 ms Serial Command 0341 Serial Command 0340 1 sec 2 sec Serial Command 0343 Serial Command 0342 3 sec 5 sec 2.
Scanner Configuration SmartScan Manual 12 Enter Setup
Chapter 3 OUTPUT INTERFACES 3.1 KEYBOARD WEDGE PARAMETERS 3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE 1) Read this label to activate Keyboard Wedge and select a keyboard type. 2) Read the “Decimal Value” label on page 57. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0000 Activate & Select Keyboard Type … NO. KEYBOARD TYPE NO.
Scanner Configuration SmartScan Manual 3.1.2 ALPHABETS LAYOUT Serial Command 0313 Serial Command 0312 AZERTY Serial Command 0314 QWERTZ 3.1.3 DIGITS LAYOUT Serial Command 0008 Serial Command 0007 Upper Row Serial Command 0009 Lower Row 3.1.4 CAPITAL LOCK TYPE Serial Command 0011 Serial Command 0010 Shift Lock Serial Command 0012 Capital Lock 3.1.
Chapter 3 Output Interfaces 3.1.6 ALPHABETS TRANSMISSION Serial Command 0006 Serial Command 0005 Ignore Case 3.1.7 DIGITS TRANSMISSION Serial Command 0014 Serial Command 0013 Numeric Key 3.1.8 ALT COMPOSING Serial Command 0334 Serial Command 0335 Yes 3.1.9 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay. 2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
Scanner Configuration SmartScan Manual 3.2 RS-232 PARAMETERS 3.2.1 ACTIVATE RS-232 INTERFACE Serial Command 0001 Activate RS-232 Interface 3.2.2 BAUD RATE Serial Command 0016 Serial Command 0023 115200 bps Serial Command 0017 38400 bps Serial Command 0018 19200 bps <9600 bps> Serial Command 0020 Serial Command 0019 4800 bps 2400 bps Serial Command 0022 Serial Command 0021 1200 bps 600 bps (for 1200 only) 3.2.
Chapter 3 Output Interfaces 3.2.4 DATA BITS Serial Command 0035 Serial Command 0034 <8 bits> 7 bits 3.2.5 FLOW CONTROL Serial Command 0043 Serial Command 0042 Scanner Ready Serial Command 0045 Serial Command 0044 Data Ready Invert Data Ready 3.2.6 INTER-CHARACTER DELAY 1) Read this label to specify the inter-character delay. 2) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 3) Read the “Validate” label on the same page to complete this setting.
Scanner Configuration SmartScan Manual 3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200) 3.3.1 ACTIVATE WAND EMULATION Serial Command 0306 Activate Wand Emulation 3.3.2 NORMAL STATE Serial Command 0303 Serial Command 0302 High 3.3.3 BAR STATE Serial Command 0305 Serial Command 0304 Low 3.3.4 MODULE TIME Serial Command 0363 Serial Command 0362 250 μs Serial Command 0364 500 μs Serial Command 0365 <1 ms> 1.
Chapter 3 Output Interfaces 3.3.
Scanner Configuration SmartScan Manual 20 Enter Setup
Chapter 4 SYMBOLOGY SETTINGS 4.
Scanner Configuration SmartScan Manual Serial Command 0109 Serial Command 0108 Enable Addon 2 Serial Command 0110 Serial Command 0111 Enable Addon 5 EAN-8 Serial Command 0099 Serial Command 0098 Disable No Addon Serial Command 0101 Serial Command 0100 Enable Addon 2 Serial Command 0102 Serial Command 0103 Enable Addon 5 FRENCH PHARMACODE Serial Command 0079 Serial Command 0078 Enable ITALIAN
Chapter 4 Symbology Settings INTERLEAVED 25 Serial Command 0083 Serial Command 0082 Disable MATRIX 25 Serial Command 0085 Serial Command 0084 Enable MSI Serial Command 0113 Serial Command 0112 Enable PLESSEY Serial Command 0115 Serial Command 0114 Enable RSS-14 & EXPANDED Serial Command 413 Serial Command 0412 Enable RSS-14 & RSS Expanded RSS LIMITED Serial Command 0415 Serial Command 0414 Enable TELEPEN Serial Command
Scanner Configuration SmartScan Manual UPC-A Serial Command 0292 Serial Command 0291 Serial Command 0293 Disable No Addon Serial Command 0294 Enable Addon 2 Serial Command 0296 Serial Command 0295 Enable Addon 5 UPC-E Serial Command 0093 Serial Command 0092 Serial Command 0094 Disable No Addon Serial Command 0095 Enable Addon 2 Serial Command 0097 Serial Command 0096 Enable Addon 5 24
Chapter 4 Symbology Settings 4.
Scanner Configuration SmartScan Manual 4.3 CODE 25 PARAMETERS 4.3.1 INDUSTRIAL 25 Serial Command 0081 Serial Command 0080 Disable START / STOP PATTERN SELECTION Serial Command 0131 Serial Command 0130 Interleaved 25 Serial Command 0132 Matrix 25 CHECKSUM VERIFICATION Serial Command 0140 Serial Command 0139 Enable CHECKSUM TRANSMISSION Serial Command 0142 Serial Command 0141 Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max.
Chapter 4 Symbology Settings Serial Command 0211 Serial Command 0210 Max. Length Min. Length Serial Command 0209 Serial Command 0210 Enable Fixed Length … Serial Command 0211 Fixed Length 1 Fixed Length 2 4.3.
Scanner Configuration SmartScan Manual CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond). 4) Read the “Validate” label on the same page to complete this setting. Serial Command 0212 Serial Command 0214 Enable Max./Min. Length … Serial Command 0215 Max. Length Min.
Chapter 4 Symbology Settings CHECKSUM VERIFICATION Serial Command 0148 Serial Command 0147 Enable CHECKSUM TRANSMISSION Serial Command 0150 Serial Command 0149 Disable CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 2) Read the labels for Max. /Min or fixed length separately. 3) Read the “Decimal Value” label on page 57 for the desired inter-character delay (millisecond).
Scanner Configuration SmartScan Manual 4.4 CODE 39 PARAMETERS Serial Command 0075 Serial Command 0074 Disable START / STOP TRANSMISSION Serial Command 0117 Serial Command 0116 Enable CHECKSUM VERIFICATION Serial Command 0119 Serial Command 0118 Enable CHECKSUM TRANSMISSION Serial Command 0121 Serial Command 0120 Disable STANDARD / FULL ASCII CODE 39 Serial Command 0123 Serial Command 0122 Full ASCII 4.
Chapter 4 Symbology Settings 4.
Scanner Configuration SmartScan Manual 4.
Chapter 4 Symbology Settings 4.9 EAN-128 PARAMETERS Serial Command 0105 Serial Command 0104 Enable CODE ID TRANSMISSION Serial Command 0435 Serial Command 0434 Enable FIELD SEPARATOR Serial Command 0301 Enable Field Separator … 1) Read this label to enable field separator. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting.
Scanner Configuration SmartScan Manual 4.10 MSI PARAMETERS Serial Command 0113 Serial Command 0112 Enable CHECKSUM VERIFICATION Serial Command 0168 Serial Command 0167 Double Modulo 10 Serial Command 0169 Modulo 10 & 11 CHECKSUM TRANSMISSION Serial Command 0171 Serial Command 0170 Both Digits Transmitted Serial Command 0172 Both Digits Not Transmitted CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min.
Chapter 4 Symbology Settings Serial Command 0223 Serial Command 0222 Max. Length Min.
Scanner Configuration SmartScan Manual 4.11 PHARMACODE PARAMETERS 4.11.1 FRENCH PHARMACODE Serial Command 0079 Serial Command 0078 Enable CHECKSUM TRANSMISSION Serial Command 0129 Serial Command 0128 Disable 4.11.
Chapter 4 Symbology Settings 4.
Scanner Configuration SmartScan Manual 4.13 RSS FAMILY PARAMETERS CODE ID SELECTION Serial Command 0433 Serial Command 0432 ]C1 <]e0> 4.13.1 RSS-14 Serial Command 413 Serial Command 0412 Enable RSS-14 & RSS Expanded CODE ID TRANSMISSION Serial Command 0419 Serial Command 0418 Disable APPLICATION ID TRANSMISSION Serial Command 0425 Serial Command 0424 Disable CHECKSUM TRANSMISSION Serial Command 0429 Serial Command 0428 Disable 4.13.
Chapter 4 Symbology Settings CODE ID TRANSMISSION Serial Command 0421 Serial Command 0420 Disable APPLICATION ID TRANSMISSION Serial Command 0427 Serial Command 0426 Disable CHECKSUM TRANSMISSION Serial Command 0431 Serial Command 0430 Disable 4.13.
Scanner Configuration SmartScan Manual 4.
Chapter 4 Symbology Settings 4.
Scanner Configuration SmartScan Manual 4.
Chapter 5 DATA OUTPUT FORMAT 5.1 CHARACTER SUBSTITUTION 1) Read the label to enable either character substitution by set. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-]. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0310 Serial Command 0309 Set 1 Set 2 Serial Command 0311 Set 3 5.
Scanner Configuration SmartScan Manual 5.3.2 SELECT PRE-DEFINED CODE ID Serial Command 9962 Serial Command 9961 Code ID Set 1 Code ID Set 2 Serial Command 9964 Serial Command 9963 Code ID Set 3 Code ID Set 4 Serial Command 9965 Code ID Set 5 5.3.3 CHANGE CODE ID 1) Read the label of a specific symbology to change its code ID. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID.
Chapter 5 Data Output Format Serial Command 0268 Serial Command 0261 Matrix 25 Serial Command 0269 MSI Serial Command 0442 Plessey Telepen Serial Command 0265 Serial Command 0270 UPC-A UPC-E 5.
Scanner Configuration SmartScan Manual EAN-8 Serial Command 0245 Serial Command 0244 Enable Length Code EAN-13 Serial Command 0247 Serial Command 0246 Enable Length Code FRENCH PHARMACODE Serial Command 0229 Serial Command 0228 Enable Length Code ITALIAN PHARMACODE Serial Command 0227 Serial Command 0226 Enable Length Code INDUSTRIAL 25 Serial Command 0231 Serial Command 0230 Enable Length Code
Chapter 5 Data Output Format MSI Serial Command 0249 Serial Command 0248 Enable Length Code PLESSEY Serial Command 0251 Serial Command 0250 Enable Length Code TELEPEN Serial Command 0439 Serial Command 0438 Enable Length Code UPC-A Serial Command 0290 Serial Command 0289 Enable Length Code UPC-E Serial Command 0243 Serial Command 0242 Enable Length Code 47 Update
Scanner Configuration SmartScan Manual 48 Enter Setup
Chapter 6 DATA EDITING 6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS FORMAT 1 Serial Command 0282 Serial Command 0281 Enable Editing Format 1 FORMAT 2 Serial Command 0284 Serial Command 0283 Enable Editing Format 2 FORMAT 3 Serial Command 0286 Serial Command 0285 Enable Editing Format 3 APPLY ALL 3 EDITING FORMATS TO TELEPEN Serial Command 0444 Serial Command 0443 Disable All 6.1.
Scanner Configuration SmartScan Manual 6.2 EDITING FORMAT PARAMETERS 6.2.1 SELECT FORMAT TO CONFIGURE START FORMAT PROGRAMMING Serial Command 9982 Serial Command 9981 Configure Format 1 Configure Format 2 Serial Command 9983 Configure Format 3 END FORMAT PROGRAMMING Serial Command 9980 End Format Programming 6.2.2 RESTORE DEFAULT FORMAT Serial Command 9990 Restore Default Format 6.2.
Chapter 6 Data Editing Serial Command 0526 Serial Command 0524 EAN-8 No Addon Serial Command 0528 EAN-8 Addon 2 Serial Command 0532 EAN-8 Addon 5 EAN-13 No Addon Serial Command 0536 Serial Command 0534 EAN-13 Addon 2 EAN-13 Addon 5 Serial Command 0504 Serial Command 0590 EAN-128 / RSS Serial Command 0502 French Pharmacode Serial Command 0506 Italian Pharmacode Industrial 25 Serial Command 0510 Serial Command 0508 Interleaved 25 Matrix 25 Serial Command 0540 Serial Command 0538 MSI Serial Comman
Scanner Configuration SmartScan Manual 2) Read the “Decimal Value” label on page 57 for the desired length. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0549 Serial Command 0548 Max. Length Min. Length MATCHING STRING 1) Read the label to specify a matching string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting.
Chapter 6 Data Editing FIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0555 Select Field Terminating String … Serial Command Serial Command 0553 0552 Include String Discard String 1) Read the label to divide field by field length.
Scanner Configuration SmartScan Manual Serial Command 0558 Divide Field by Field Length … FIELD 3 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0563 Select Field Terminating String … Serial Command Serial Command 0561 0560 Include String Discard String 1) Read the label to divide field by field length.
Chapter 6 Data Editing 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0566 Divide Field by Field Length … FIELD 5 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecimal Value” label on page 58 for the desired character string. 3) Read the “Validate” label on the same page to complete this setting.
Scanner Configuration SmartScan Manual Serial Command 0576 Additional Field 5… 6.2.6 FIELD TRANSMISSION SEQUENCE 1) Read the “Start” label to begin with programming the field transmission sequence. 2) Program the transmission sequence by reading the desired fields as well as additional fields. 3) Read the “End” label on the same page to complete this setting.
Appendix I NUMERAL SYSTEMS DECIMAL SYSTEM DECIMAL Serial Command 9901 Serial Command 9900 0 Serial Command 9902 1 Serial Command 9903 2 3 Serial Command 9905 Serial Command 9904 4 5 Serial Command 9907 Serial Command 9906 6 Serial Command 9908 7 Serial Command 9909 8 9 VALIDATE THE VALUES Serial Command 9994 Validate 57 Update
Scanner Configuration SmartScan Manual HEXADECIMAL SYSTEM HEXADECIMAL Serial Command 9901 Serial Command 9900 0 Serial Command 9902 1 Serial Command 9903 2 3 Serial Command 9905 Serial Command 9904 4 5 Serial Command 9907 Serial Command 9906 6 Serial Command 9908 7 Serial Command 9909 8 9 Serial Command 9911 Serial Command 9910 A B Serial Command 9913 Serial Command 9912 C D Serial Command 9915 Serial Command 9914 E F VALIDATE THE VALUES Serial Command 9994 Validate 58 Enter Setup
Appendix II KEYBOARD WEDGE TABLE & ASCII TABLE KEYBOARD WEDGE TABLE 0 0 1 2 3 4 5 6 7 8 F2 SP 0 @ P ` p b 1 INS F3 ! 1 A Q a q c 2 DLT F4 " 2 B R b r d 3 Home F5 # 3 C S c s e 4 End F6 $ 4 D T d t f 5 Up F7 % 5 E U e u g 6 Down F8 & 6 F V f v h 7 Left F9 ' 7 G W g w i 8 BS F10 ( 8 H X h x j 9 HT F11 ) 9 I Y i y k A LF F12 * : J Z j z B Right ESC + ; K [ k { C PgUp Exec , < L \
Scanner Configuration SmartScan Manual KEY STATUS Serial Command 9931 Serial Command 9930 Add Shift Add Left Ctrl Serial Command 9933 Serial Command 9932 Add Left Alt Add Right Ctrl Serial Command 9934 Add Right Alt Note: Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.
Appendix III HOST SERIAL COMMANDS SERIAL COMMANDS #@nnnn Purpose To configure the scanner. Remarks nnnn – the four digits of command parameters. For example, “9952” is to list the current Code ID settings. “0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d” #@ - - - - Purpose To halt the scanner. Remarks “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d” #@ . . . . Purpose To resume operation.
Scanner Configuration SmartScan Manual For the scanner to change the buzzer frequency to 4 kHz and beep – #@0047 #@//// For the scanner to change the buzzer frequency to 1 kHz and beep – #@0049 #@//// 62
Appendix IV UPGRADING FIRMWARE HOW TO UPGRADE 1166/1266 FIRMWARE You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest scanners when there is more than one scanner connected to your computer, either via (1) the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a fully charged battery.
Scanner Configuration SmartScan Manual Enter Setup Download 6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer. (Download.exe requires version 2.3 or later!) Open the firmware update “1x66-xx.shx”, and select the correct COM port. Baud rate – 115,200 bps Data bit –8 Parity – None Flow control – None 7) The scanner will automatically restart itself when upgrading firmware is completed successfully.
Appendix IV Upgrading Firmware HOW TO UPGRADE 3666 FIRMWARE 1) Connect the power supply cord from the 3666 cradle to a proper power outlet. 2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port. 3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle. Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds. Both labels can be located at the bottom of the cradle.
Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead. Enter Setup Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.
Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequence for the scanner to get the firmware version of the 3666 cradle. If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead. Enter Setup Version 5) The current version information of the 3666 cradle will be displayed. For example, Version = V1.