User guide
    49 
Update 
  Chapter 2
 Selectin
g
 Output Interface
2.3 DIRECT USB HID 
For USB HID, connect the scanner to the USB port of PC. Run any text editor on the 
computer, and the scanned data will be transmitted to the computer. 
HID Settings 
Defaults 
Keyboard Type  PCAT (US) 
Digits Layout  Normal 
Capital Lock Type  Normal 
Capital Lock State  Off 
Alphabets Transmission  Case-sensitive 
Digits Transmission  Alphanumeric keypad 
Kanji Transmission  Disable 
Inter-Character Delay  0 (ms) 
Inter-Function Delay  0 (ms) 
2.3.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE 
When USB HID interface is activated, it will have to select a keyboard type to complete 
this setting.   
 Activate  
Direct USB HID & 
Select Keyboard 
Type…
1)  Read the barcode above to activate USB HID and select a keyboard type.   
2)  Read the “
Decimal Value” barcode on page 193. Refer to the table below for the 
number of desired keyboard type.   
3)  Read the “Validate” barcode on the same page to complete this setting. 
USB HID 
By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —   
No.  Keyboard Type  No.
Keyboard Type 
64  PCAT (US)  71  PCAT (Belgium) 
65  PCAT (French)  72  PCAT (Spanish) 
66  PCAT (German)  73  PCAT (Portuguese) 
67  PCAT (Italy)  74  PS55 A01-2 (Japanese) 
68 PCAT (Swedish)  75 User-defined table 
69  PCAT (Norwegian)  76  PCAT (Turkish) 
70  PCAT (UK)  77  PCAT (Hungarian) 