User guide

56
MIRROR 5250 Emulator
User Guide
One time, Two times,
or Three times
The higher the reading security is (that is, the more redundancy the user
selects), the slower the reading speed gets.
If "Three Times" is selected, it will take a total of four consecutive
successful decodings of the same barcode to make the reading valid.
Time-out 3 sec.
0~255 (second) Set the maximum time for decoding to continue during a scan attempt.
It applies to the following scan modes only –
Aiming mode
Laser mode
Auto Off mode
Auto Power Off mode
SYMBOLOGY SETTINGS TABLE
CCD/Laser Engine Description Default
Codabar Enable
Transmit Start/Stop
Character
Decide whether to include the start/stop characters in the
data being transmitted.
If "Transmit Start/Stop Characters" is desired, select one
set:
abcd / abcd
abcd / tn*e
ABCD / ABCD
ABCD / TN*E
No
Code 128 Enable
GS1-128 (EAN-128) Enable
Transmit Code ID (for
EAN-128)
Decide whether to include Code ID (“]C1”) will be included
in the data being transmitted.
No
Replace Field
Separator
Decide whether to replace the field separator. If the
barcode contains Field Separator “0x1D”, it will be
changed to the desired Field Separator. For example, type
the desired character “;” (semicolon) as the new field
separator. Then if the barcode contains Field Separator
“0x1D”, it will be changed to “;”.
No
ISBT 128 Enable
Industrial 25 (Discrete 25) Enable
Start/Stop Selection
T
his decides the readability of all 2 of 5 symbology
variants. For example, flight tickets actually use an
Industrial 2 of 5 barcode but with Interleaved 2 of 5
start/stop pattern. In order to read this barcode, the
start/stop pattern selection parameter of Industrial 2 of 5
should set to "Interleaved 25".
Industrial 25
Verify Check Digit Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No