User guide
62 
MIRROR 5250 Emulator
User Guide 
SYMBOLOGY SETTINGS TABLE 
LR/ELR Engine  Description  Default 
Codabar  Disable 
Transmit Start/Stop 
Character 
Decide whether to include the start/stop characters in the 
data being transmitted. 
No 
Select Length 
  Any Length 
  One or two fixed lengths 
  Range (1~55) 
Any Length 
Code 128  Enable 
GS1-128  Enable 
Replace Field 
Separator 
Decide whether to replace the field separator. If the 
barcode contains Field Separator “0x1D”, it will be 
changed to the desired Field Separator. For example, type 
the desired character “;” (semicolon) as the new field 
separator. Then if the barcode contains Field Separator 
“0x1D”, it will be changed to “;”. 
No 
ISBT 128  Enable 
Industrial 25 (Discrete 25)  Enable 
Select Length 
  Any Length 
  One or two fixed lengths 
  Range (1~55) 
Any Length 
Interleaved 25  Enable 
Convert to EAN-13  Convert a 14-character barcode into EAN-13 if the 
following requirements are met: 
  The barcode must have a leading 0 and a valid EAN-13 
check digit. 
No 
Verify Check Digit  Decide whether to verify the check digit. If desired, select 
one of the algorithms below. If the check digit
is incorrect, 
the barcode will not be accepted. 
  No 
  USS algorithm 
  OPCC algorithm 
No 
Transmit Check Digit  Decide whether to include the check digit
in the data being 
transmitted. 
No 
Select Length 
  Any Length 
  One or two fixed lengths 
  Range (1~55) 
Any Length 
Code 39  Enable 
Convert to Code 32  Convert to Italian Pharmacode.  No 
Verify Check Digit  Decide whether to verify the check digit. If the check digit 
is incorrect, the barcode will not be accepted. 
No 