User guide
60 
MIRROR VT Emulator User Guide 
One time, Two times, 
or Three times 
The higher the reading security is (that is, the more redundancy the user 
selects), the slower the reading speed gets. 
  If "Three Times" is selected, it will take a total of four consecutive 
successful decodings of the same barcode to make the reading valid. 
Time-out  3 sec. 
0~255 (second)  Set the maximum time for decoding to continue during a scan attempt.   
It applies to the following scan modes only –   
  Aiming mode 
  Laser mode 
  Auto Off mode 
  Auto Power Off mode 
SYMBOLOGY SETTINGS TABLE 
CCD/Laser Engine  Description  Default 
Codabar  Enable 
Transmit Start/Stop 
Character 
Decide whether to include the start/stop characters in the 
data being transmitted. 
If "Transmit Start/Stop Characters" is desired, select one 
set: 
  abcd / abcd 
  abcd / tn*e 
  ABCD / ABCD 
  ABCD / TN*E 
No 
Code 128  Enable 
GS1-128 (EAN-128)  Enable 
Transmit Code ID (for 
EAN-128) 
Decide whether to include Code ID (“]C1”) will be included 
in the data being transmitted. 
No 
Replace Field 
Separator 
Decide whether to replace the field separator. If the 
barcode contains Field Separator “0x1D”, it will be 
changed to the desired Field Separator. For example, type 
the desired character “;” (semicolon) as the new field 
separator. Then if the barcode contains Field Separator 
“0x1D”, it will be changed to “;”. 
No 
ISBT 128  Enable 
Industrial 25 (Discrete 25)  Enable 
Start/Stop Selection 
T
his decides the readability of all 2 of 5 symbology 
variants. For example, flight tickets actually use an 
Industrial 2 of 5 barcode but with Interleaved 2 of 5 
start/stop pattern. In order to read this barcode, the 
start/stop pattern selection parameter of Industrial 2 of 5 
should set to "Interleaved 25". 
Industrial 25 
Verify Check Digit  Decide whether to verify the check digit. If the check digit 
is incorrect, the barcode will not be accepted. 
No 