Specifications

101
Update
Chapter 5
Defining Output Format
5.4 CODE ID
Up to two characters for Code ID can be configured for each symbology. To make the
Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you
can select one and make necessary changes on it.
If "Bluetooth HID" is configured for interface, Key Type and Key Status will then
become applicable. You may decide whether or not to apply Key Status when “Normal
Key” is selected for Key Type. Refer to
Keyboard Wedge Table.
Key Type
Key Status
Scan Code Up to 1 scan code values are allowed. N/A
Normal Key Up to 2 character strings are allowed.
Default setting
Add Shift
Add Left Ctrl
Add Left Alt
Add Right Ctrl
Add Right Alt
Add Break
For example, read labels for [Add Shift] and
the character [A].
Note: "]C1" is the Code ID of EAN-128 barcodes; "]e0" is the default Code ID of RSS
barcodes.
5.4.1 SELECT PRE-DEFINED CODE ID
Code ID options Set 1 Set 2 Set 3 Set 4 Set 5
Code 39 A C Y M A
Italian Pharmacode A C Y M A
French Pharmacode A C Y M A
Industrial 25 C H H H S
Interleaved 25 D I Z I S
Matrix 25 E G G G S
Codabar F N X N F
Code 93 I L L L G
Code 128 H K K K C
UPC-E S E C E E
EAN-8 P B B FF E
EAN-13 M A A F E