Specifications
    145 
Update 
You may configure in which format the collected data will be output to the host 
computer. Barcode read by the scanner will be processed in the following sequence –   
1)  Perform character substitution on the data scanned. 
2)  Add 
Code ID and Length Code to the front of the data:[Code ID][Length Code][Data] 
3)  Process the whole data in step 2 with user formats. Data is now divided into fields by 
user specified rules. Refer to 
Chapter 6 Applying Formats for Data Editing. 
4)  Add 
Prefix Code and Suffix Code before transmission:[Prefix Code][Processed 
Data][Suffix Code]
IN THIS CHAPTER 
5.1 Letter Case ..............................................................145 
5.2 Character Substitution...............................................146 
5.3 Prefix/Suffix Code .....................................................154 
5.4 Code ID...................................................................155 
5.5 Length Code ............................................................159 
5.6 Multi-Barcode Editor..................................................163 
5.7 Removal of Special Character .....................................166 
5.1 LETTER CASE 
By default, the alphabets transmission is case-sensitive, meaning that the alphabets will 
be transmitted according to their original case. Ignoring the original letter case, select 
[Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output 
data in lower case only. 
*Normal 
Upper Case 
Lower Case 
Chapter 5