User Manual
Table Of Contents
- Important Notices
 - Release Notes
 - Introduction
 - Quick Start
 - Understanding the Barcode Scanner
 - Selecting Output Interface
 - Setting up a WPAN Connection
 - Specifications
 
    67 
Update 
  Chapter 2 
錯誤!  使用  [常用]  索引標籤將  Heading 1  套用到您想要在此處顯示的文字。 
2.4 USB HID VIA 3610 
For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to 3610. 
Run any text editor on your computer, and the scanned data will be transmitted to the 
computer. 
HID Settings  Defaults 
Keyboard Type  PCAT (US) 
Digits Layout  Normal 
Capital Lock Type  Normal 
Capital Lock State  Off 
Alphabets Transmission  Case-sensitive 
Digits Transmission  Alphanumeric keypad 
Inter-Function Delay  0 (ms) 
2.4.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE 
When USB HID interface is activated, you will have to select a keyboard type to complete 
this setting.  
Activate 
3610 USB HID & Select 
Keyboard Type… 
1)  Read the barcode above to activate USB HID and select a keyboard type.  
2)  Read the “
Decimal Value”  barcode  on page 錯誤!  尚未定義書籤。. Refer to the table 
below for the number of desired keyboard type.  
3)  Read the “Validate” barcode on the same page to complete this setting. 
USB HID 
By default, the keyboard type is set to PCAT (US). The following keyboard types are supported —  
No.  Keyboard Type  No.  Keyboard Type 
64  PCAT (US)  71  PCAT (Belgium) 
65  PCAT (French)  72  PCAT (Spanish) 
66  PCAT (German)  73  PCAT (Portuguese) 
67  PCAT (Italy)  74  PS55 A01-2 (Japanese) 
68  PCAT (Swedish)  75  User-defined table 
69  PCAT (Norwegian)  76  PCAT (Turkish) 
70  PCAT (UK)     