User's Manual
98
1800 Series Handheld RFID Reader Reference Manual
4.3.1 TIME STAMP SECTION
You can specify individual field to each section. Time Stamp section is divided into 7 fields
as year, month, day, weekday, hour, minute and second. Separators can be defined among
fields to make more clear presentation. It is up to 6 separators can be specified to Time
Stamp section.
Time Stamp Sequence
Issue “#@dat_tseq=” command to configure the fields of Time Stamp section. You can set
the parameter to ‘0’ to disable the field.
Command:
#@dat_tseq?\r
Purpose Get the Sequence Settings of Time Stamp Section
Response OK,[m],[n],[o],[p],[q],[r],[s]\r (Default m= ‘1’, n= ‘2’’, o= ‘3’, p= ‘0’, q= ‘5’, r= ‘6’, s=
‘7’)
[m]: Time Data Type in Field 1
[n]: Time Data Type in Field 2
[o]: Time Data Type in Field 3
[p]: Time Data Type in Field 4
[q]: Time Data Type in Field 5
[r]: Time Data Type in Field 6
[s]: Time Data Type in Field 7
[m]~[s] Field
‘0’
Disable this Field
‘1’
Year
‘2’
month
‘3’
day
‘4’
weekday
‘5’
Hour
‘6’
Minute
‘7’
second
ERR,[code]\r
#@dat_tseq=[m],[n],[o],[p],[q],[r],[s]\r
Purpose Set the Sequences of Field in Time Stamp Section
Response OK\r
[m]: Time Data Type in Field 1. Default = ‘1’
[n]: Time Data Type in Field 2. Default = ‘2’
[o]: Time Data Type in Field 3. Default = ‘3’
[p]: Time Data Type in Field 4. Default = ‘0’