Communication Interface
2.6 USB HID VIA 3610
For USB HID via 3610, connect 3610 to the USB port of host computer, and then connect
RFID Reader to 3610 via Bluetooth
®
. Configure the interface to USB HID via 3610 by issuing
the “#@bt_type=” command to parameter ‘6’.
To capture the data run any text editor on host computer. The scanned data will be
transmitted to the host computer.
Note: As above for a read only interface, you can not issue “#@BT_TYPE=” command to
change the Bluetooth
®
interface to 3610 directly by command.
How to connect with the 3610?
There are two parameters for “#@bt_target” command to 3610. One is Bluetooth
®
target – 3610 and
another is the serial No. of 3610.
Command:
#@bt_target?\r
Purpose Get Bluetooth
®
Target Machine
Response OK,[m],[n]\r
[m]: Bluetooth
®
Type, ‘0’ – SPP Master, ‘1’ – 3610
[n]: MACID of target Machine or S/N of 3610
ERR,[code]\r
#@bt_target=[m],[N]\r
Purpose Set Bluetooth
®
Target Machine
Response OK\r
ERR,[code]\r
Example:
HID Settings
Defaults
Keyboard Type PCAT (US)
Alphabets Layout Normal