User's Manual

Table Of Contents
126
1800 Series Handheld RFID Reader Reference Manual
5.2 FORMAT EDITING FOR HEXADECIMAL AND RAW DATA
When the data format is specified for Hexadecimal or Raw Data, you can configure the
data sections described as below:
Each section can be enabled or disabled.
Each section has individual prefix and suffix.
The sequence of sections can be adjusted.
Default Format:
Command:
#@dat_seq?\r
Purpose Get the Setting of Output Data Sequence
Response
OK,[m],[n],[o]\r (Default m=
‘1’, n= ‘2’, o= ‘3’)
[m]: Section in sequence 1
[n]: Section in sequence 2
[o]: Section in sequence 3
Data section will be one of the following:
[m]/[n]/[o] Section
‘0’ Disable this section
‘1’ Count section
‘2’ Time Stamp section
‘3’ UHF Data section
ERR,[code]\r
#@dat_seq=[m],[n],[o]\r
Purpose Set Output Data Sequence
Response OK\r
ERR,[code]\r