1800 Series Handheld RFID Reader Reference Manual
Executing:
Function
Key Operation LEDs Status
Command1 <F1>+<F2> <F 1: Executing>
Command2 <F1>+<F2> <F2> < F→→1: Executing>
Group3 Others (Yellow LED1):
Press <F1>+<F2> to switch to Group3 with Yellow LED1. The Group3 is defined to 4
commands. Press <F2> to switch among the Commands or press <F1> to execute the
command. The LED status will return to normal mode when you idle about 3 seconds
during configuration.
Command1: Enable/Disable memory mode.
(As serial command: “#@sys_memen=1/0” )
Command2: Clear data memory.
(As serial command: #@sys_memclr)
Command3: Select USB virtual COM driver (Switch between CDC and SiliconLab).
(As serial command: #@usb_type=127/128)
Note: By default, the value of the reader for USB Virtual COM driver is CDC (usb
type=127). Press <F1> one time upon command3 to switch to SiliconLab type if
you are using SiliconLab driver as a Virtual COM connection. Wrong VCOM type
selection will cause disconnection to the host.
Command4:
a. Breaks the current connection if Bluetooth
®
connection exists.
b. If there’s no Bluetooth
®
connection, resets the connection type to default –
SPP slave.
(depending on the Bluetooth
®
connection status, it is to run the serial command
“#@bt_disc” or “#@bt_reset”)
Press <F2> to switch between Command 1, 2, 3 and 4
Command1 Command2 Command3 Command4
Note: Except for function keys, you can also issue command to break or reset the
Bluetooth
®
connection. Refer to 3.3.1 Break a Connection and 3.3.2 Reset a
Connection
.