2.5.3 INTER-CHARACTER DELAY
By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254
in units of millisecond, to match the computer response time of the keyboard interface.
Such delay time is inserted between every character being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Options
Parameter Description
‘0’ (Default) ‘0’~‘254’ The range is from 0 to 254 in units of millisecond.
2.5.4 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254
in units of milliseconds, to match the computer response time of the keyboard interface.
Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted.
The longer the delay time is, the slower the transmission speed will be.
Options
Parameter Description
‘0’ (Default) ‘0’~‘254’ The range is from 0 to 254 in units of millisecond.
2.5.5 HID CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch. You may configure the RFID
Reader to “By Character” to process data one character at a time.
Options
Parameter Description
Batch Processing
(Default)
‘0’ Process data by Batch.
By Character ‘1’ Process data by Character