User Manual

166
Enter Setup
1660 Barcode Scanner
User Guide
EXAMPLE
Without using the scanner to read the above setup labels for configuring the 3610 dongle,
you may run HyperTerminal.exe on the host computer to send serial commands to 3610
via USB Virtual COM or HID.
1) Connect 3610 to the USB port of PC.
2) The Communication LED will indicate when 3610 can accept serial commands after
initializing. Refer to the table below.
Communication LED
Meaning
--- Blue,
solid
Initialize
Red,
solid
Blue,
solid
Serial command mode with USB Virtual COM: wait 3 seconds for
starting a serial command
Red,
flashing
Blue,
solid
Serial command mode with USB HID: wait 3 seconds for pressing
[NumLock] or [CapsLock] 5 times via keyboard
If the output interface is USB Virtual COM, run HyperTerminal.exe on your
computer. While the Communication LED on 3610 is purple (red and blue both
come on), type the serial command within 3 seconds.
If the output interface is USB HID, press the “NumLock” or “CapsLoack” key via
the keyboard 5 times within 3 seconds while the Communication LED on 3610 is
solid blue with red flashing. This will change the interface from USB HID to USB
Virtual COM and the Communication LED will become purple (red and blue both
come on). Then, run HyperTerminal.exe on your computer. While the
Communication LED on 3610 is purple, type the serial command within 3 seconds.
After configuring via serial commands, the interface will be reset to USB HID after
re-connecting 3610.