User Manual

31
Update
Chapter 1 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
1.6.5 AUTO POWER OFF MODE
The scanner will start scanning once the trigger is pressed.
The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout
period re-counts after each successful decoding.
Note: Refer to “Delay between Re-read” and “Scanning Timeout”.
1.6.6 AIMING MODE
The scanner will aim at a barcode once the trigger is pressed, and start scanning when
the trigger is pressed again within one second.
The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout
expires.
Aiming Timeout
You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second.
1. Read the label above to specify the time interval before aiming ends. (It is set to 1 by default.)
2. Read the “Decimal Value
” label on page 169. For example, read “1” and “0” for the scanner to
automatically shut down after being idle for 10 seconds.
3. Read the “Validate” label on the same page to complete this setting.
Auto Power Off Mode
Aiming Mode
Aiming Time-Out after 1~15 seconds (*1)