User Manual

51
Update
Chapter 2 錯誤! 使用 [常用] 索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
2.3 USB HID VIA 3610
For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to 3610.
Run any text editor on your computer, and the scanned data will be transmitted to the
computer.
HID Settings
Defaults
Keyboard Type PCAT (US)
Digits Layout Normal
Capital Lock Type Normal
Capital Lock State Off
Alphabets Transmission Case-sensitive
Digits Transmission Alphanumeric keypad
Inter-Function Delay 0 (ms)
Send “NR” to Host Disable
2.3.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE
When USB HID interface is activated, you will have to select a keyboard type to complete
this setting. By default, BT HID is activated on the 1660 scanner, and the keyboard type
is set to PCAT (US).
1) Read the label above to activate USB HID and select a keyboard type.
2) Read the “Decimal Value
” label on page 169. Refer to the table below for the number
of desired keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Activate USB HID & Select Keyboard Type …