User Manual
Table Of Contents
- IMPORTANT NOTICES
- RELEASE NOTES
- INTRODUCTION
- QUICK START
- UNDERSTANDING THE BARCODE SCANNER
- SELECTING OUTPUT INTERFACE
- SETTING UP A WPAN CONNECTION
- CHANGING SYMBOLOGY SETTINGS
- 4.1 CODABAR
- 4.2 CODE 25 – INDUSTRIAL 25
- 4.3 CODE 25 – INTERLEAVED 25
- 4.4 CODE 25 – MATRIX 25
- 4.5 CODE 39
- 4.6 CODE 93
- 4.7 CODE 128
- 4.8 EAN-8
- 4.9 EAN-13
- 4.10 GS1-128 (EAN-128)
- 4.11 ISBT 128
- 4.12 MSI
- 4.13 FRENCH PHARMACODE
- 4.14 ITALIAN PHARMACODE
- 4.15 PLESSEY
- 4.16 GS1 DATABAR (RSS FAMILY)
- 4.17 TELEPEN
- 4.18 UPC-A
- 4.19 UPC-E
- DEFINING OUTPUT FORMAT
- APPLYING FORMATS FOR DATA EDITING
- SPECIFICATIONS
- Appendix I - FIRMWARE UPGRADE
- Appendix II - HOST SERIAL COMMANDS
- Appendix III - KEYBOARD WEDGE TABLE
- Appendix IV - NUMERAL SYSTEMS
143
Update
Chapter 5
Defining Output Format
5.6.1 EDIT A CONCATENATION OF BARCODES
1) Read the label above to start editing a concatenation of barcodes.
2) Code Type setting – read the “Hexadecimal Value
” label on page 188 for Code Type of
the (first) barcode. For example, read “4” and “1” for Code 39.
Code Type
Symbology Code Type Symbology
41 (A) Code 39 4F (O) EAN-8 with Addon 5
42 (B) Italian Pharmacode 50 (P) EAN-13
43 (C) French Pharmacode) 51 (Q) EAN-13 with Addon 2
44 (D) Industrial 25 52 (R) EAN-13 with Addon 5
45 (E) Interleaved 25 53 (S) MSI
46 (F) Matrix 25 54 (T) Plessey
47 (G) Codabar (NW7) 55 (U) GS1-128 (EAN-128)
48 (H) Code 93 56 (V) UPC-A
49 (I) Code 128 57 (W) UPC-A with Addon 2
4A (J) UPC-E0 / UPC-E1 58 (X) UPC-A with Addon 5
4B (K) UPC-E with Addon 2
4C (L) UPC-E with Addon 5 5A (Z) Telepen
4D (M) EAN-8 5B ( [ ) GS1 DataBar (RSS)
4E (N) EAN-8 with Addon 2
3) Barcode Length setting – read the “Decimal Value
” label on page 187 for the 4-digit
length of the (first) barcode. For example, read “0065” for barcode length of 65
characters or read “0000” for any length.
Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix
(0x0d by default), length code, etc.
4) Matching Character setting – read the “Hexadecimal Value” label on page 188 for the
1
st
character that must be found matching in the (first) barcode. For example, read
“4” and “1” for matching character “A” as the first character in the barcode or read
“00” for any character.
5) Read twice the “F” label on page 188 (“FF”) to complete the setting o
f each barcode.
6) Read the “Validate” label to end the editing of the barcode set.
Edit Output Sequence