User's Manual

11
4.1.4 Capital Lock Status
In order to send alphabets with correct case, the scanner needs to know the capital
lock status of the keyboard. Incorrect settings may result in reversed case of
alphabets being transmitted. There are 3 options to this parameter : On, Off, or Auto
Detection. If this parameter is set to Auto Detection, the scanner will automatically
detect the capital lock status of the keyboard before it transmits data.
4.1.5 Alphabets Transmission
User can choose how alphabets are sent by configuring this parameter. The
alphabets can be sent according to their case (the Case Sensitive option), or the
case is ignored (the Ignore Case option) when transmitting.
4.1.6 Digits Transmission
User can choose how the scanner transmits digits by configuring this parameter.
The scanner can transmit digits by using the alphanumeric key or by using the
numeric keypad. The Num Lock status of the keyboard should be ON if numeric
keypad option is selected.
4.1.7 Inter-Character Delay
An inter-character delay of 0 to 255 ms can be configured to match the computer
response time of the keyboard interface. The delay time configured is inserted
between transmitting every character. The longer the delay time configured, the
slower the transmission speed will be. The inter-character delay is zero by default.
4.2 RS232 Interface
User can select the desired, flow control, baud rate, parity, and data bits to be used
in this output interface.
1 2 3 4
! @ # $
Digits on Upper Row
N
umeric Key Pad
Alpha Numeric Key
12
4.2.1 Baud Rate / Parity / Data Bits
The supported baud rate, parity, and data bit are listed below.
Baud Rate : 115200 / 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600
Parity : None / Even / Odd
Data bit : 8 / 7
4.2.2 Flow Control
The user can further configure the flow (handshake) control method to be used.
The available options are listed below.
No Flow Control
Scanner Ready : The scanner will activate the RTS signal after power on.
After each good read the scanner will then wait for the CTS signal becomes
active. The data will not be sent until CTS signal becomes active.
Data Ready : The RTS signal will be activated after each good read. The
scanner will then wait for the CTS signal becomes active. The data will not
be sent until CTS signal becomes active.
Inverted Data Ready : It is like the Data Ready flow control, but the RTS
signal level is inverted.
4.2.3 Inter-Character Delay
An inter-character delay of 0 to 255 ms can be configured to match the computer
response time. The delay time configured is inserted between transmitting every
character. The longer the delay time configured, the slower the transmission speed
will be. The inter-character delay is zero by default.
4.3 USB Interface
A USB interface is also available. For installation instructions please refer to the
separate diskette included with your scanner.
4.4 Memory Parameters
The 1160 can work offline and store the reading data into the internal Flash
memory for later upload to the host. The stored data can be up to 32Kbytes.
4.4.1 Memory Mode
This setting enables or disables the memory function of the scanner.
4.4.2 Clear Data
The CLEAR label will enable the user to CLEAR or ERASE the data in the
scanner’s memory. The user must also scan the CONFIRM label immediately after
the CLEAR label.