User's Manual

13
4.4.3 Send Data
This enables the user to transmit the data in the scanner’s memory to the host. The
interface selected by the user will be used for the transmission. During the
transmission the red LED of 1160 will be flashing.
4.4.4 Memory Data Delay
This will enable the user to set a delay between each data records in memory at
time of transmission.
14
5. Symbology Parameters
This section describes user configurable parameters that are pertaining to barcode
symbologies.
5.1 Code39
Standard / Full ASCII Code 39 : User can choose to read either Standard
Code 39 or Full ASCII Code 39 by configuring this parameter.
Start/Stop Transmission : This parameter specifies whether the start/stop
characters of Code 39 are included in the data being transmitted.
Checksum Verification : This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.
Checksum Transmission : This parameter specifies whether the checksum
character are included in the data being transmitted.
5.2 Italy / French Pharmacode
For Italy /French Pharmacode, there is always a checksum character included in the
barcode. So the checksum verification is always performed when decoding these
symbologies. User though can choose whether the checksum character is to be
transmitted or not. The start / stop transmission of this code shares the same setting
of Code 39.
Checksum Transmission: This parameter specifies whether the checksum
character is included in the data being transmitted.
5.3 Industrial / Interleave / Matrix 25
Start / Stop Selection: This parameter provides the readability of all 2 of 5
symbology variants. For example, flight tickets actually use an Industrial 25
barcode but with Interleave 25 start / stop. In order to read this barcode, the
start / stop selection parameter of Industrial 25 should set to ‘Interleave
25.
Checksum Verification: This parameter specifies whether the scanner will
perform checksum verification when decoding barcodes. If the checksum is
incorrect, the barcode will not be read.
Checksum Transmission: This parameter specifies whether the checksum
character is included in the data being transmitted.
Code Length Qualification: Because of the weak structure of the 2 of 5
codes, a partial scan has a high probability of decoding as a valid but shorter
2 of 5 codes (known as short scan). To prevent this kind of undesired
reading, the Code Length settings can help to insure that the correct code is