User's Manual

134
9200 Mobile Compute
r
Reference Manual
CCD READER SETTINGS
Barcode Reader Description
CCD Reader Tap the Barcode Reader button to configure reader settings for the
CCD scan engine.
Refer to the Reader Settings Table in Appendix II - CCD (SM1).
Decode Session Timeout Sets the maximum time (configurable from 1 to 9 sec) for the
decoding process during a scan attempt. The default value is 3 sec.
Redundancy Level Sets how many successful readings should be done before linear
barcodes such as Codabar, MSI, and Interleaved 2 of 5 can be
decoded. Levels 1 to 4 available.
The readings needed for each level are as follows:
Level 1 The following barcodes must be successfully read
twice before being decoded: Codavar, MSI, Industrial
25 (Discrete 25), Interleaved 25.
Level 2 All barcodes must be successfully read twice before
being decoded.
Level 3 All barcodes must be successfully read twice before
being decoded, except for the following which must be
read three times: MSI, Industrial 25 (Discrete 25),
Interleaved 25.
Level 4 All barcodes must be successfully read three times
before being decoded.
Scan Mode Sets the reader’s scanning behavior. Default is “Laser”.
“Continuous” to decode the same barcode repeatedly or decode
different barcodes in a continuous motion.
“Laser” for scanning by pressing the scan trigger.
Timeout Between Symbols Only available for Continuous mode. The default value is 1 sec.
1D LASER READER SETTINGS
Barcode Reader Description
Laser Reader Tap the Barcode Reader button to configure reader settings for the
laser scan engine.
Refer to the Reader Settings Table in Appendix III -ʳLaser (SE955).
Decode Session Timeout Sets the maximum time (configurable from 1 to 9 sec) for the
decoding process during a scan attempt. The default value is 3 sec.