Instructions
Table Of Contents
- Safety precautions
- DISCLAIMER
- CONTENTS
- Revision log
- SYMBOLS
- 1.- VERIFICATION UPON RECEPTION
- 2.- Product description
- 3.- DEVICE installation
- 3.1.- PRELIMINARY RECOMMENDATIONS
- 3.2.- BATTERY INSTALLATION
- 3.4.- MYeBOX 480V ~ PSU ADAPTER : POWER SUPPLY ADAPTER
- 3.5.- VOLTAGE CABLES
- 3.6.- CURRENT CLAMPS
- 3.7.2.- MYeBOX 1500
- 3.8.- CONNECTION DIAGRAMS
- 3.8.1.- Three-phase network measuring with a 4-wire connection,
- MYeBOX 150.
- 3.8.2.- Three-phase network measuring with a 4-wire connection,
- MYeBOX 1500.
- 3.8.3.- Three-phase network measuring with a 3-wire connection, MYeBOX 150 and MYeBOX1500.
- 3.8.4.- Three-phase network measuring with a 3-wire connection and ARON connection, MYeBOX 150 and MYeBOX 1500.
- 3.8.5.- Two-phase network measuring with a 3-wire connection,
- MYeBOX 150.
- 3.8.6.- Two-phase network measuring with a 3-wire connection,
- MYeBOX 1500.
- 3.8.7. - Single-phase network measurement, phase to phase, with a 2-wire connection, MYeBOX 150 and MYeBOX 1500.
- 3.8.8.- Single-phase network measurement, phase to neutral, with a 2-wire connection, MYeBOX 150.
- 3.8.9.- Single-phase network measurement, phase to neutral, with a 2-wire connection, MYeBOX 1500.
- 3.8.10.- Detail of the current measurement connection.
- 3.8.11.- Leakage current connection, ILeak. (MYeBOX 1500 model)
- 3.9.- REGISTERING AND UPDATING THE DEVICE
- 4.- OPERATION
- 5.- display
- 6.- CONFIGURATION
- 6.2.2.- Measurement name
- 6.2.1.- Name of the device
- 6.1.12.- Exit
- 6.1.11.- Save
- 6.1.10.- Frequency
- 6.1.9.- Primary winding of the leakage current transformer
- 6.1.7.- Primary winding of the neutral current transformer
- 6.1.6.- Neutral clamp scale
- 6.1.5.- Primary winding of the current transformer
- 6.1.4.- Phase clamp scale
- 6.1.3.- Secondary voltage
- 6.1.2.- Primary voltage
- 6.3.2.- Gap, Sag
- 6.3.1.- Overvoltage, swell
- 6.2.5.- Exit
- 6.2.4.- Save
- 6.2.3.- Type of installation
- 6.4.1.- Wi-Fi Configuration
- 6.3.6.- Exit
- 6.3.5.- Save
- 6.3.4.- Transients, Disturb
- 6.3.3.- Outage, Interruption
- 6.4.9.- PIN
- 6.4.8.- APN, password
- 6.4.7.- APN, user
- 6.4.6.- APN, access point name
- 6.4.5.- Enabling 3G communications
- 6.4.4.- Password
- 6.4.3.- WPS
- 6.4.2.- SSID
- 6.5.- SETUP MENU: MEMORY SETUP
- 6.6.- SETUP MENU: RESET FACTORY SETUP
- 6.1.1.- Rated voltage
- 6.1.8.- Clamp scale for measuring the leakage current, ILeak
- 7.- WIRELESS COMMUNICATIONS
- 8.- MOBILE APPLICATION MYeBOX
- 9.- mYeBOX Cloud
- 10.- software UPDATE
- 11.- TECHNICAL FEATURES
- 12.- Maintenance AND TECHNICAL SERVICE
- 13.- GUARANTEE
- 14.- CE CERTIFICATE
17
Instruction Manual
MYeBOX 150 - MYeBOX 1500
Table 5 (Continuation):Clamps and transformers for measuring the phase current and the neutral current�
Type Scale Measurement range Accuracy
(1)
Transformer ���/ 0�250A
-
1% ... 200% In 0.5% (1% ... 200% In)
(1)
Accuracy is given by the following measurement conditions for input 2V: exclusion of errors produced by the
clamps and external voltage transformers, with a range in temperature of 5 ... 45 ºC and power factor 0 ... 1.
The 3 phase clamps L1, L2 and L3 must be of the same type. Otherwise, an
error event is logged in the EVA le; in this case measurements can be taken
with the device using the features of the L1 clamp.
Measurement of the leakage current, ILeak (MYeBOX 1500 model):
Table 6: Clamps and transformers for measuring the leakage current�
Type Scale Measurement range Accuracy
(2)
CFG-5 - 0.01 ... 5 A 0.2% (3 % ... 200% In)
CFG-10 - 0.02 ...10 A 0.2% (3 % ... 200% In)
Transformer WG - 1% ... 500% In 1% (10% ... 200% In)
(2)
Accuracy is given by the following measurement conditions for input 2V: exclusion of errors produced by the
clamps and external voltage transformers, with a range in temperature of 5 ... 45 ºC and power factor 0 ... 1.
Note: Transformers must be connected to the device with connectors and the corresponding
EEPROM in order for them to work.
3.7.- DEVICE TERMINALS
3�7�1�- MYeBOX 150
Table 7:List of terminals on the lower face of the MYeBOX 150�
Device terminals on the lower face of the MYeBOX 150
1: U1, Voltage input L1 5: I1, Current input L1
2: U2, Voltage input L2 6: I2, Current input L2
3: U3, Voltage input L3 7: I3, Current input L3
4: UN, Voltage input neutral
8: IN, Neutral current input
1 2 3 4 5 6 7 8
Figure 10:MYeBOX 150 terminals, lower face�