User Manual
CDB5466U
6 DS676DB1
1.2.2.2 High-pass Filter
By removing the offset from either channel, no error component will be generated at DC when computing the active
(real) power. Input pin HPF defines the three options, and J33 defines the state of the HPF pin.
– HPF is enabled in the voltage channel when jumper J33 = GND.
– HPF is enabled in the current channel when pin HPF is connected to pin FOUT.
– High-Pass Filter (HPF) is disabled when jumper J33 = VD+. 
1.2.2.3 Energy Pulse Outputs
The CS5466 provides three output pins for energy registration. The E1 and E2 pins provide a simple interface from
which energy can be registered. These pins are designed to directly connect to a stepper motor or electromechanical
counter. The E1
 and E2 outputs are available on header J11, pins 1 and 3, respectively. The pulse rate on the E1
and E2 pins are in the range of 0 to 4 Hz and all frequency settings are optimized to be used with standard meter
constants. The FOUT pin is designated for system calibration, the pulse rate can be selected to reach a frequency
of 8000 Hz. The FOUT output is available on header J11, pin 5.
Maximum Input Range IGAIN1 IGAIN0
J31 J32
±250mV 10x
±50mV 50x
±25mV 100x
±16.67mV 150x
Table 4. Current Channel PGA Selection 
HPF
High Pass Filter Option J33
Voltage 
Channel
HPF Option 
is in Voltage 
Channel
Current 
Channel
HPF Option 
is in Current 
Channel
Disabled
HPF Option 
is Disabled
Table 5. HPF Option Selection 
O 
O 
 VD+
  IGAIN1
 GND
 (Default) 
O 
O 
 VD+
 IGAIN0
 GND
 (Default) 
O 
O 
 VD+
 IGAIN1
 GND
O 
O 
 VD+
 IGAIN0
 GND
O 
O 
 VD+
 IGAIN1
 GND
O 
O 
 VD+
 IGAIN0
 GND
O 
O 
 VD+
 IGAIN1
 GND
O 
O 
 VD+
 IGAIN0
 GND
O O VD+
O O FOUT
O 
 GND
 HPF
  HPF
 HPF
(Default)
O O VD+
O O FOUT
O 
 GND
 HPF
  HPF
 HPF
O O VD+
O O FOUT
O 
 GND
 HPF
  HPF
 HPF