User guide
110 ©Copyright 2006 Cirrus Logic, Inc. DS651PM25
CobraNet Programmer’s Reference
Management Interface Variable Reference 
6.4.13 Synchronization
Name
syncConductorClock
Description
Selects sample clock source when acting as network conductor. 
0x0 - Internal mode. 
0x1 - External Word Clock mode. 
0x10 - Not supported on CobraNetSilicon Series devices. (Internal with External Sample 
Synchronization mode.) 
0x14 - Not supported on CobraNet Silicon Series devices. (External Master Clock with External 
Sample Synchronization mode.) 
Host Address
0x60000
SNMP Object ID
1.3.6.1.4.1.2680.1.1.8.1
Type
Integer
Attributes
Read/write - Persistent
Default Value
0
Implemented Version
2.2.1
Name
syncPerformerClock
Description
Selects sample clock source when acting as a performer. Values are the same as documented 
above for syncConductorClock. External clocks applied must be externally synchronized to the 
conductor.
Host Address
0x60001
SNMP Object ID
1.3.6.1.4.1.2680.1.1.8.2
Type
Integer
Attributes
Read/write - Persistent
Default Value
0
Implemented Version
2.2.1