User guide
CobraNet Programmer’s Reference
Management Interface Variable Reference 
DS651PM25 ©Copyright 2006 Cirrus Logic, Inc. 67
Name
firmwareMfgVersion
Description
A manufacturer assigned minor revision number for firmware. A non-zero value indicates 
manufacturer has made some modification to the standard firmware as released by Cirrus Logic.
Host Address
0x6
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.7
Type
Integer
Attributes
Read-only
Implemented Version
2.1.0
Name
firmwareRestart
Description
Reboots the interface when set to a non-zero value. Invoking this function will cause loss of 
communications. The interface will attempt to send a response to an SNMP set request before 
restarting. Due to the nature of SNMP, receipt of such a response by the manager is not 
guaranteed. Invoking this feature via HMI will cause the HMI to become inoperable until the 
interface has completed re-initialization. A successful restart can be verified by reading the 
sysUpTime variable. sysUpTime returns to 0 following a restart.
A restart via SNMP may adversely affect an HMI connected host processor. Care should be taken to 
insure that a host processor attempting to communicate via HMI during reset can recover from the 
HMI’s failure to respond and, further, that the host processor will continue to function properly 
following reinitialization of the MI variables to their default or persistent values.
Host Address
0x100
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.8
Type
Integer
Attributes
Read/Write
Default Value
0
Implemented Version
2.6.3. Not implemented on 32-bit platforms.
Name
firmwareFreeCycles
Description
Free CPU cycles in thousandths. For example, 475 means 47.5% of CPU cycles are free, i.e., 
running idle loop.
Host Address
0x9
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.11
Type
Integer32 for CS18101-based firmware. Integer24 for Motorola-based firmware.
Attributes
Read-only
Implemented Version
2.9.12 for Motorola-based firmware; 2.10.5 for CS1810xx-based firmware.