Manual
CRD5378
DS639RD2 15
2.2.1.6 Common Mode Bias
Differential analog signals into the CS3301A/02A amplifiers are required to be biased to the center of the
power supply voltage range, which for bipolar supplies is near ground potential. Resistors to create the
common mode bias are selected based on the sensor impedance and may need to be modified from the
CRD5378 defaults depending on the sensor to be used. Refer to the recommended operating bias con-
ditions for the selected sensor, which are available from the sensor manufacturer.
Land Common Mode Filter Specification  Value 
Common Mode Capacitance  10 nF + 10% 
Common Mode Resistance 
200 Ω 
Common Mode -3 dB Corner @ 6 dB/octave  80 kHz + 10% 
Land Differential Filter Specification  Value 
Differential Capacitance  10 nF + 10% 
Differential Resistance 
200 Ω + 200 Ω = 400 Ω 
Differential -3 dB Corner @ 6 dB/octave  40 kHz + 10% 
Marine Common Mode Filter Specification  Value 
Hydrophone Group Capacitance  128 nF + 10% 
Differential Resistance 
412 kΩ + 2 kΩ 
-3 dB Corner @ 6 dB/octave  3 Hz + 10% 
Specification Value 
Geophone Sensor Bias Resistance 
20 kΩ || 20 kΩ = 10 kΩ 
Hydrophone Sensor Bias Resistance 
18 MΩ || 18 MΩ = 9 MΩ 