6.13.8 Configuration Default
The Configuration Default register is used by software as an aid in determining the configuration of jacks
and devices attached to the codec. At the time the codec is first powered on, this register is internally load-
ed with default values indicating the typical system use of this particular pin/jack. After this initial loading,
it is completely codec opaque, and its state, including any software writes into the register, must be pre-
served across reset events such as Link Reset or Codec Reset (the Function Reset Verb). Its state need
not be preserved across power level changes.
Get Parameter Command Format:
Set Parameter Command Format:
Response Format: 
Bits [31:0] are sticky and will not be reset by a Link Reset or a Codec Reset:
Bits [31:28] Bits [27:20] Bits [19:8] Bits [7:0]
CAd = X Node ID = 0Fh Verb ID = F1Ch Payload = 00h
Bits [31:28] Bits [27:20] Bits [19:8] Bits [7:0]
CAd = X Node ID = 0Fh Verb ID = 71Ch Payload = xxh (Config bits [7:0])
CAd = X Node ID = 0Fh Verb ID = 71Dh Payload = xxh (Config bits [15:8])
CAd = X Node ID = 0Fh Verb ID = 71Eh Payload = xxh (Config bits [23:16])
CAd = X Node ID = 0Fh Verb ID = 71Fh Payload = xxh (Config bits [31:24])
Bits Type Default Description
31:30 Read/Write 00b
Port Connectivity (PCON): The port complex is 
connected to a jack.
29:24 Read/Write 000010b
Location (LOC): This field indicates the physical 
location of the jack or device to which the pin 
complex is connected. Set to External | Front.
23:20 Read/Write Ch
Default Device (DD): Indicates the intended use 
of the connection is for S/PDIF In.
19:16 Read/Write 4h
Connection Type (CTYP): Indicates the type of 
physical connection is RCA jack.
15:12 Read/Write Eh
Color (COL): This field indicates the color of the 
physical jack for use by software. The color 
selected is White.
11:8 Read/Write 0h
Miscellaneous (MISC): No PDC override.
7:4 Read/Write Fh
Default Association (DA): This field is used by 
software to group Pin Complex (and therefore 
jacks) together into functional blocks to support 
multichannel operation. All jacks with the same 
association number may be assumed to be 
grouped together. A value of all ‘0’s is reserved. 
A value of all ‘1’s in this field indicates that the 
Association has the lowest priority.
3:0 Read/Write 0h
Sequence (SEQ): This field indicates the order 
of the jacks in the association group.