SWITCHING CHARACTERISTICS - CONTROL PORT - SPI FORMAT 
Inputs: Logic 0 = GND, Logic 1 = VLC, C
L
=20pF.
Notes:
18. t
spi
 is only needed before first falling edge of CS after RST rising edge. t
spi
 = 0 at all other times.
19. Data must be held for sufficient time to bridge the transition time of CCLK.
20. For F
SCK
 < 1 MHz. 
Parameter Symbol Min Max Unit
CCLK Clock Frequency f
sclk
-6MHz
RST
 Rising Edge to CS Falling t
srs
500 - ns
CCLK Edge to CS
 Falling (Note 18) t
spi
500 - ns
CS
 High Time Between Transmissions t
csh
1.0 - µs
CS
 Falling to CCLK Edge t
css
20 - ns
CCLK Low Time t
scl
66 - ns
CCLK High Time t
sch
66 - ns
CDIN to CCLK Rising Setup Time t
dsu
40 - ns
CCLK Rising to DATA Hold Time  (Note 19) t
dh
15 - ns
Rise Time of CCLK and CDIN  (Note 20) t
r2
- 100 ns
Fall Time of CCLK and CDIN  (Note 20) t
f2
- 100 ns
t
r2
t
f2
t
dsu
t
dh
t
sch
t
scl
CS
CCLK
CDIN
t
css
t
csh
t
spi
t
srs
RST