User`s manual
9-11 Copyright 2009 Cirrus Logic, Inc. DS734UM7
Pin Description
CS485xx Hardware User’s Manual
 9.2.1.2 Ground
For two-layer circuit boards, care should be taken to have sufficient grounding between the DSP and parts in 
which it will be interfacing (DACs, ADCs, S/PDIF Receivers, microcontrollers, and especially external 
memory). Insufficient grounding can degrade noise margins between devices resulting in data integrity 
problems.
 9.2.1.3 Decoupling
It is necessary to decouple the power supply by placing capacitors directly between the power and ground of 
the CS485xx. Each pair of power/ground pins (VDD1/GND1, etc.) should have its own decoupling capacitor. 
The recommended procedure is to place a 0.1 uF capacitor as close as physically possible to each power 
pin connected with a wide, low-inductance trace. A bulk capacitor of at least 10 uF is recommended for each 
power plane.
 9.2.2 PLL Filter
 9.2.2.1 Analog Power Conditioning
In order to obtain the best performance from the CS485xx internal PLL, the analog power supply VDDA 
must be as noise free as possible. A ferrite bead and two capacitors should be used to filter the VDDIO to 
generate VDDA. This power scheme is shown in the 
Typical Connection diagrams.
Table 9-3. Core and I/O Ground Pins
LQFP-48 
Pin #
Pin Name Pin Type Pin Description
4 GND1
Input
Core Ground.
9 GND2
22 GND3
33 GND4
7 GNDIO1
I/O Ground
19 GNDIO2
30 GNDIO3
40 GNDIO4
Table 9-4. PLL Supply Pins
LQFP-48 
Pin #
Pin Name Pin Type Pin Description
48 VDDA Input
PLL supply. This voltage must be 3.3V. This 
must be clean, noise-free analog power.
46 GNDA Input
PLL ground. This ground should be as noise-
free as possible.