Owner manual
DS700PP1 33
CS53L21
4.9 Recommended Power-Down Sequence
To minimize audible pops when turning off or placing the A/D in standby,
1. Mute the ADC’s. 
2. Set the PDN bit in the power control register to ‘1’b. The A/D will not power down until it reaches a fully
muted sate. Do not remove MCLK until after the part has fully muted. Note that it may be necessary to
disable the soft ramp and/or zero cross volume transitions to achieve faster muting/power down.
3. Bring RESET
 low. 
ADC Initialization
Software Mode
Registers setup to 
desired settings.
RESET = Low?
No Power
1. No audio signal 
generated.
Off Mode (Power Applied)
1. No audio signal generated.
2. Control Port Registers reset 
to default.
Control Port 
Active
Control Port Valid 
Write Seq. within 
10 ms?
Hardware Mode 
 Minimal feature 
set support.
PDN bit = '1'b?
Sub-Clocks Applied
1. LRCK valid.
2. SCLK valid.
3. Audio samples 
processed.
Valid 
MCLK/LRCK 
Ratio?
No
Yes
No
Yes
No
Yes
Yes
No
Normal Operation 
Audio signal generated per control port or stand-
alone settings.
PDN bit set to '1'b 
(software mode only)
Standby Mode
1. No audio signal generated.
2. Control Port Registers retain 
settings.
Reset Transition
1. Pops suppressed.
Power Off Transition
1. Audible pops.
ERROR: Power removed
Valid 
MCLK Applied?
No
 20 ms delay
Charge Caps
1. VQ Charged to 
quiescent voltage.
2. Filtx+ Charged.
2048 internal 
MCLK cycle delay
RESET = Low
Figure 17. Initialization Flow Chart