Manual
CS5464
DS682F3 33
8.3 Page 1 Registers
8.3.1 DC Offset for Current (I1
OFF 
, I2
OFF
 ) and Voltage (V1
OFF
 , V2
OFF
 )
Address: 0 (I1
OFF
), 2 (V1
OFF
), 7 (I2
OFF
), 9 (V2
OFF
)
Default = 0
DC offset registers 
I1
OFF
 & V1
OFF
 (I2
OFF
 & V2
OFF
) are initialized to zero on reset. During DC offset calibration, 
selected registers are written with the inverse of the DC offset measured. The application program can also write 
the DC offset register values. These are two's complement values in the range of -1.0
 value  1.0, with the 
binary point to the right of the MSB.
8.3.2 Gain for Current (I1
GAIN 
, I2
GAIN
 ) and Voltage (V1
GAIN
 , V2
GAIN
 )
Address: 1 (I1
GAIN
), 3 (V1
GAIN
), 8 (I2
GAIN
), 10 (V2
GAIN
)
Default = 1.0
Gain registers 
I1
GAIN
 & V1
GAIN
 (I2
GAIN
 & V2
GAIN
)
are initialized to 1.0 on reset. During AC or DC gain calibration, 
selected register are written with the multiplicative inverse of the gain measured. These are unsigned fixed-point 
values in the range of 0
 value  4.0, with the binary point to the right of the second MSB.
8.3.3 Power Offset (P1
OFF
 , P2
OFF
 )
Address: 4 (P1
OFF 
), 11 (P2
OFF
 )
Default = 0
Power offset 
P1
OFF
 (P2
OFF
) is added to instantaneous power and averaged over a low-rate interval to yield 
P1
AVG 
(P2
AVG
) register results. It can be used to reduce systematic energy errors. These are two's complement 
values in the range of -1.0
 value  1.0, with the binary point to the right of the MSB.
8.3.4 AC Offset for Current (I1
ACOFF 
, I2
ACOFF 
) and Voltage (V1
ACOFF 
, V2
ACOFF 
)
Address: 5 (I1
ACOFF
), 6 (V1
ACOFF
), 12 (I2
ACOFF
), 13 (V2
ACOFF
) 
Default = 0
AC offset registers 
I1
ACOFF
 & V1
ACOFF
 (V
ACOFF
 & V2
ACOFF
)
are initialized to zero on reset. These are added to 
the RMS results before being stored to the RMS result registers. They can be used to reduce systematic errors 
in the RMS results. These are two's complement values in the range of -1.0
 value  1.0, with the binary point 
to the right of the MSB.
MSB LSB
-(2
0
)2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
MSB LSB
2
1
2
0
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
.....
2
-16
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
MSB LSB
-(2
0
)2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
MSB LSB
-(2
0
)2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23