Test report #20000282F FCC 15.231 for MI-4800B FCC ID: LDK102039
Tested February 2, 2000
AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (616) 424-7014 91442
Exhibit N: Page 3 of 4
ETS 300.826 CE Mark Approval
Depending on the product, the Notified Body lab will test the entire OEM product to the required EMC standard.
The lab will then submit one report to the local authority, which will then issue the CE mark for the product that will
be accepted in the other EC countries. The tests can include the following but are not limited to:
EN 55022 Line Conducted
EN 1000-4-2 Electrostatic Discharge
EN 1000-4-3 RF Field Immunity (80MHz to 1GHz)
EN 1000-4-4 Electrical Fast Transient
EN 1000-4-5 Surge / Transient
EN 1000-4-6 Line Conducted Immunity (150kHz to 80MHz)
EN 1000-4-11 Voltage Transients
EN 6001-3-2 Power Line Harmonics
EN 6001-3-3 Voltage Flicker
EN 60950 Low Voltage Directive
This series of tests can be done in the US or Canada. It is recommended but not necessary to have it done at a UL or
CSA approved lab. Upon completion of the testing, file a copy with the local European representative.