Quick Start Guide

FINAL DRAFT - CISCO CONFIDENTIAL
29
1. Determine the location where you want to mount the access point.
2. Attach two caddy fasteners to the ceilings T-rail.
3. Use the mounting bracket to adjust the distance between the caddy
fasteners so that they align with the holes in the mounting bracket.
4. Use a standard screwdriver to tighten the caddy fastener studs in place
on the T-rail. Do not overtighten.
5. Install a plastic spacer on each caddy fastener stud. The spacers legs
should contact the ceiling grid T-rail.
6. Attach the mounting bracket to the caddy fastener studs and start a Keps
nut on each stud.
7. Use a wrench or pliers to tighten the Keps nuts. Do not overtighten.
8. Attach the access point to the mounting bracket.
Attaching the Access Point to the Mounting
Bracket
Follow these steps to attach the access point to the mounting bracket.
1. Line up the three mounting pins on the access point with the large ends
of the keyhole-shaped holes on the mounting bracket.
2. Insert the access point into the keyhole shaped holes and maintain a
slight pressure to hold it in place.