User's Manual
Table Of Contents
- Cisco Aironet 1300 Series Bridge Hardware Installation Guide
- Contents
- Preface
- Overview
- Installation Overview
- Mounting and Alignment Overview
- Stacking Bridges
- Configuring the Bridge for the First Time
- Using the Web-Browser Interface
- Using the Command-Line Interface
- Troubleshooting
- Translated Safety Warnings
- Statement 84—Warning Definition
- Statement 245B—Explosive Device Proximity Warning
- Statement 332—Antenna Installation Warning
- Statement 1001—Work During Lightning Activity
- Statement 1004—Installation Instructions
- Statement 1005—Circuit Breaker
- Statement 1024—Ground Conductor
- Statement 1040—Product Disposal
- Statement 1052—Installing and Grounding the Antenna
- Declarations of Conformity and Regulatory Information
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- Department of Communications—Canada
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity for RF Exposure
- Guidelines for Operating Cisco Aironet Access Points and Bridges in Japan
- Administrative Rules for Cisco Aironet Bridges in Taiwan
- Bridge Specifications
- Channels and Antenna Settings
- Glossary
- Index
CISCO CONFIDENTIAL - First Draft
C-2
Cisco Aironet 1300 Series Bridge Hardware Installation Guide
OL-5048-01
Appendix C Bridge Specifications
Humidity 0 to 90% (condensing) Power Injector:
0 to 90% (non-condensing)
Power Module:
0 to 95% (non-condensing)
Operational Vibration 0.001 G
2
/Hz from 5-100 Hz 0.001 G
2
/Hz from 5-100 Hz
Non-Operational
Vibration
0.01 G
2
/Hz from 5-100 Hz 0.01 G
2
/Hz from 5-100 Hz
Environmental Testing
Compliance
The enclosure has been successfully tested and is in
compliance with a NEMA Type 4 (IP56) enclosure
rating.
—
Weight 2.5 lbs (1.13 kg) Power injector—0.8 lbs (0.36 kg)
Power Module—1.0 lbs (0.5 kg)
Input Voltage 48 VDC nominal (supplied by dual-coax cables)
8.5 VDC (minimum)
53 VDC (maximum)
Power injector:
10 VDC to 53VDC
Power module:
90 to 264 VAC at TBD to TBD Hz
Power Consumption 13W (typical)
TBD W (maximum)
TBD W (maximum)
Radio Output Power 100, 50, 30, 20, 5, or 1 mW
(at 1, 2, 5.5, and 11 Mbps)
30, 20, 10, 5, or 1 mW
(at 6, 9, 12, 18, 24, 48, and 54 Mbps)
(Depending on the regulatory domain in which the
access point is installed)
Power injector:
18W (maximum at 48 VDC) supplied to
the bridge through dual-coax cables
Power module:
18W (maximum at 48VDC)
Frequency 2.400 to 2.497 GHz
(Depending on the regulatory domain in which the
access point is installed)
—
Modulation IEEE 802.11b-compliant radio:
Direct Sequence Spread Spectrum (DSSS)
Complementary Code Keying (CCK)
IEEE 802.11g-compliant radio:
Orthogonal Frequency Division Multiplex
(OFDM)
—
Subcarrier modulation CCK (5.5 Mbps and 11 Mbps)
BPSK (1 Mbps, 6 Mbps and 9 Mbps)
QPSK (2 Mbps, 12 Mbps and 18 Mbps)
16-QAM (24 Mbps and 36 Mbps)
64-QAM (48 Mbps and 54 Mbps)
—
Table C-1 Bridge, Power Injector, and Power Module Specifications (continued)
Category Bridge Power Injector and Power Module