User's Manual
Table Of Contents
- Cisco Aironet 1300 Series Bridge Hardware Installation Guide
- Contents
- Preface
- Overview
- Installation Overview
- Mounting and Alignment Overview
- Stacking Bridges
- Configuring the Bridge for the First Time
- Using the Web-Browser Interface
- Using the Command-Line Interface
- Troubleshooting
- Translated Safety Warnings
- Statement 84—Warning Definition
- Statement 245B—Explosive Device Proximity Warning
- Statement 332—Antenna Installation Warning
- Statement 1001—Work During Lightning Activity
- Statement 1004—Installation Instructions
- Statement 1005—Circuit Breaker
- Statement 1024—Ground Conductor
- Statement 1040—Product Disposal
- Statement 1052—Installing and Grounding the Antenna
- Declarations of Conformity and Regulatory Information
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- Department of Communications—Canada
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity for RF Exposure
- Guidelines for Operating Cisco Aironet Access Points and Bridges in Japan
- Administrative Rules for Cisco Aironet Bridges in Taiwan
- Bridge Specifications
- Channels and Antenna Settings
- Glossary
- Index
CISCO CONFIDENTIAL - First Draft
C-3
Cisco Aironet 1300 Series Bridge Hardware Installation Guide
OL-5048-01
Appendix C Bridge Specifications
Data rates IEEE 802.11g-compliant radio:
100, 50, 30, 20, 5, or 1 mW (at 1, 2, 5.5 and
11 Mbps)
30, 20, 10, 5, or 1 mW (at 6, 9, 12, 18, 24, 48,
and 54 Mbps)
(Depending on the regulatory domain in which the
access point is installed)
—
Non-overlapping
channels
3 —
Antenna Integrated antenna
13-dBi patch array
Some external antennas:
2.2 dBi omnidirectional
5.2-dBi omnidirectional
12-dBi omnidirectional
9-dBi patch
10 dBi yagi
13.5 dBi yagi
15-dBi sector
21-dBi dish
(Depending on the regulatory region)
—
Environmental Air
Space
The 1300 series bridge provides adequate fire
resistance and low smoke-producing characteristics
suitable for operation in a building's environmental
air space, such as above suspended ceilings, in
accordance with Section 300-22(C) of the National
Electrical Code (NEC) and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1,
C22.1.
Caution The power injectors and the power
modules are not tested to UL 2043
and should not be placed in a
building’s air-handling spaces, such
as above suspended ceilings.
Safety Bridge:
UL 60950
UL 2043
CSA C22.2 No. 60950
IEC 60950
EN 60950
Power injector and power module:
UL 60950
CSA C22.2 No. 60950
IEC 60950
EN 60950
Note The power injector and the power
module must be used in an indoor
environment.
Table C-1 Bridge, Power Injector, and Power Module Specifications (continued)