Resetting to Default Configuration
If you forget your password that allows you to configure the access point, you
may need to completely reset the configuration. You can use the MODE
button on the access point to reset the configuration.
Note These steps reset all configuration settings to factory defaults,
including passwords, WEP keys, the IP address, and the SSID.
Using the MODE Button
Follow these steps to delete the current configuration and return all access
point settings to the factory defaults by using the MODE button:
1. Open the access point cover (refer to the “How to Open the Top Cover”
section on page 2).
2. Disconnect power from the access point (the power jack for external
power or the Ethernet cable for in-line power).
3. Press and hold the MODE button while you reconnect power to the
access point.
4. Continue pressing the MODE button until the Ethernet LED turns
amber. (approximately 2 to 3 seconds). Then release the button.