Figure 2-31 Inserting RJ-45 Connector into the Ethernet Port Opening in Case
Step 8 Slide the liquid tight adapter towards the access point, and screw the threaded end of the adapter into the
access point, and hand-tighten.
Step 9 Use an adjustable wrench, a 22 mm socket, or a Sealcon S-2200-WR wrench to tighten the threaded end
of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 10 Use an adjustable wrench and tighten the round end of the adapter to 2.7 to 3.2 ft lbs (3.66 to 4.34 Nm).
Step 11 Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 12 Route your Ethernet cable, and cut off any excess cable.
Step 13 Install an RJ-45 connector on the unterminated cable end, and insert it into the power injector. For
typical installation components see
Figure 2-2.
Step 14 Turn on power to the power injector.
1 Liquid tight adapter 3 RJ-45 connector
2 Ethernet port opening in access point case 4 Shielded outdoor-rated Ethernet (CAT5e or
better) cable