User Manual
Table Of Contents
- Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
- Preface
- Objectives
- Audience
- Organization
- Conventions
- Related Documents
- Finding the Product Serial Number
- Obtaining Documentation, Support, and Security Guidelines
- About the 1532 Access Point
- Hardware Models
- Hardware Features
- Network Deployment Examples
- Unpacking the Access Point
- Tools and Hardware
- Warnings
- Safety Information
- Avoiding Damage to Radios in a Testing Environment
- Installation Guidelines
- Mounting the Access Point
- Installation Options
- Access Point Mounting Orientation
- Wall Mounting the Access Point with the Fixed Mounting Kit
- Pole Mounting the Access Point with the Fixed Mount Kit
- Wall Mounting the Access Point with the Pivoting Mounting Kit
- Pole Mounting the Access Point with the Pivoting Mounting Kit
- Horizontally Mounting the Access Point with Optional Horizontal Mount Plate
- Installing AP Cover or Solar Shield (AIR-ACC1530-CVR=)
- Installing Antennas
- Grounding the Access Point
- Powering the Access Point
- Configuring the Access Point
- What to Do Next
- Guidelines for Using the Access Points
- Important Notes
- Controller MAC Filter List
- Using DHCP Option 43
- Monitoring the Access Point LEDs
- Verifying Controller Association
- Changing the Bridge Group Name
- Access Point Power Injector
- Using the Reset Button
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- Industry Canada
- Declaration of Conformity for RF Exposure
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC & Medical Directive 93/42/EEC
- Declaration of Conformity for RF Exposure
- Guidelines for Operating Cisco Aironet Access Points in Japan
- Administrative Rules for Cisco Aironet Access Points in Taiwan
- Operation of Cisco Aironet Access Points in Brazil
- Overview
- Configuring Option 43 for 1000, 1500, and 1530 Series Access Points
- Configuring Option 43 for 1100, 1130, 1200, 1240, 1250, 1300, 1520, and 1530 Series Access Points
REVIEW DRAFT
2-21
Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
OL-30864-01
Chapter 2 Installing the Access Point
Mounting the Access Point
To mount the access point onto a vertical pole or streetlight pole, follow these steps:
Step 1 Select a mounting location on the pole to mount the access point. You can attach the access point to any
pole with a diameter from 2 to 8 inches (5.1 to 40.6 cm).
Note If you will be using a streetlight power tap adapter, position the access point within 3 ft (1 m) of the
outdoor light control.
Step 2 Mount the pivot bracket base to the pole using either one set of the adjustable band clamps or the screw
clamp (the screw clamp can be used on a pole that is not more than 3 inches in diameter).
Step 3 Position the pole clamp bracket on the pole as needed before tightening the metal bands. Tighten the
metal bands only enough to hold the bracket base in place, from sliding along the pole. Fully tighten the
bands only after the access point is positioned.
Step 4 Match the holes in the bracket plate to the holes in the back of the access point.
Step 5 Screw an M8 x12 mm bolt into each of the four bolt holes (using a 10 mm box wrench or socket, torque
the bolts to 40 lbf-in) on the back side of the access point and mounting bracket. (See Figure 2-10)
Note The access point should be positioned with the LEDs on the bottom to allow viewing from the ground.
Step 6 Mount the bracket with the AP, to the bracket on the pole. Use the long screw for this, as shown in the
exploded view – see Figure 2-10.
Step 7 Point the AP in the general desired position and tighten bolt, and then tighten the clamps on the pole.
The AP can be repositioned to its final position by loosening and re-tightening the bolts.
Crimping tool for ground lug, Panduit CT0720 with
CD-720-1 die (http://onlinecatalog.paduit.com)
No
Four wall mounting screws (6mm max) No
Four wall anchors (specified for all material) No
Drill bit for wall anchors No
Electric drill and standard screwdriver No
#6 AWG ground wire No
Shielded outdoor-rated Ethernet (CAT5e or better) cable No
Grounding block No
Grounding rod No
13-mm box-end wrench or socket set No
10-mm box-end wrench No
Materials Required In Kit