User Manual
Table Of Contents
- Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
- Preface
- Objectives
- Audience
- Organization
- Conventions
- Related Documents
- Finding the Product Serial Number
- Obtaining Documentation, Support, and Security Guidelines
- About the 1532 Access Point
- Hardware Models
- Hardware Features
- Network Deployment Examples
- Unpacking the Access Point
- Tools and Hardware
- Warnings
- Safety Information
- Avoiding Damage to Radios in a Testing Environment
- Installation Guidelines
- Mounting the Access Point
- Installation Options
- Access Point Mounting Orientation
- Wall Mounting the Access Point with the Fixed Mounting Kit
- Pole Mounting the Access Point with the Fixed Mount Kit
- Wall Mounting the Access Point with the Pivoting Mounting Kit
- Pole Mounting the Access Point with the Pivoting Mounting Kit
- Horizontally Mounting the Access Point with Optional Horizontal Mount Plate
- Installing AP Cover or Solar Shield (AIR-ACC1530-CVR=)
- Installing Antennas
- Grounding the Access Point
- Powering the Access Point
- Configuring the Access Point
- What to Do Next
- Guidelines for Using the Access Points
- Important Notes
- Controller MAC Filter List
- Using DHCP Option 43
- Monitoring the Access Point LEDs
- Verifying Controller Association
- Changing the Bridge Group Name
- Access Point Power Injector
- Using the Reset Button
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- Industry Canada
- Declaration of Conformity for RF Exposure
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC & Medical Directive 93/42/EEC
- Declaration of Conformity for RF Exposure
- Guidelines for Operating Cisco Aironet Access Points in Japan
- Administrative Rules for Cisco Aironet Access Points in Taiwan
- Operation of Cisco Aironet Access Points in Brazil
- Overview
- Configuring Option 43 for 1000, 1500, and 1530 Series Access Points
- Configuring Option 43 for 1100, 1130, 1200, 1240, 1250, 1300, 1520, and 1530 Series Access Points
REVIEW DRAFT
2-42
Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
OL-30864-01
Chapter 2 Installing the Access Point
Powering the Access Point
Note Verify that the cable gland has a rubber seal and ensure that it is not damaged.
Warning
Failure to install the cable gland and rubber gasket properly will cause the cable grip to leak.
Figure 2-25 Cable Gland
Step 5
Insert the unterminated end of the Ethernet cable through the sealing nut end of the cable gland (see
Figure 2-25), and pull several inches of cable through the adapter.
Step 6 Install an RJ-45 connector on the unterminated end of the Ethernet cable using your Ethernet cable
installation tool.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
Warning
When installing the RJ-45 connector, ensure that cable gland and the rubber gasket are present and
installed properly, to avoid water leakage into the enclosure. See Figure 2-25 and Figure 2-26.
Step 7 Carefully insert the RJ-45 cable connector into the Ethernet port opening on the access point, and
connect to the internal Ethernet connector (see Figure 2-26).
1 Washer (Rubber Gasket) 2 Body
3 Sealing insert 4 Clamping claw
5 Thread-lock sealing nut