Using the Reset Button
Step 1 Using a wrench, remove the hex-shaped plug from the Console-Reset port. Do not to loose the seal
around the plug.
Step 2 Using a straightened paperclip or a small screwdriver or a pen, push the reset button for less than 10
seconds. This causes the access point to reboot (power cycle). All LEDs turn off for approximately 5
seconds, and then the LEDs will reactivate.
Step 3 Inspect the hex-shaped plug attached to the lanyard for any damage to the sealing face and the gasket. If
the gasket has any signs of damage, it should be replaced to avoid water leakage into the unit.
Step 4 Replace the hex-shaped plug back and tighten it to 15 lbf-in.