Step 6 Using a 10mm wrench, secure the AP to the bracket by tighening the bolts to the bracket;
torque to 40 in-lbf.
Step 7 Continue with the Grounding the Access Point, page 23.
Pole Mounting the Access Point with the Fixed Mount
Kit
The optional fixed mounting kit contains a mounting bracket for wall mounting or pole mounting.This kit can
be used to install the access point on a pole, mast or streetlight. It supports metal, wood or fiberglass poles
from 2 to 8 inches in diameter.
Table 2 Materials Needed to Mount the AP on a Vertical Pole
Materials Required
In Kit
One wall mount bracket
Yes
Four M6 x12mm hex head bolts
Yes
Two stainless steel band clamps (adjustable 2"5", 51127
mm)
Yes
Two stainless steel band clamps (adjustable 5"8", 127203
mm)
Yes
10 mm box-end wrench
No
Outdoor rated shielded ethernet cable
No
Ground lug (provided with the access point)
Yes
Ground block and rod
No
Crimping tool for ground lug, Panduit CT-720 with CD-720-1
die (http://onlinecatalog.panduit.com)
No
#6 AWG ground wire
No
To mount the access point onto a vertical pole or streetlight pole, follow these steps:
Step 1 Select a mounting location on the pole to mount the access point. You can attach the access point
to any pole with a diameter from 2to 8 inches (5.1 to 20.1 cm).
Note If you will be using a streetlight power tap adapter, position the access point within
3 ft (1 m) of the outdoor light control. The AC/DC adapter must be used with street light
power tap.