Step 2 Determine which size of band clamp is needed based on the pole diameter. Slide the two clamps
through the top and bottom set of mounting slots (see Figure 8) and mount the bracket to the
pole.
Step 3 Wrap the band clamps around the pole and slide them into the second set of top and bottom
mounting slots on the bracket. Lightly tighten the clamps. Only tighten them enough to keep the
bracket from sliding down the pole.
Step 4 Screw an M6 bolt into each of the four bolt holes on the back side of the access point. Do not screw
the bolt in all the way. Leave a gap of about 0.13" (3.3mm).
Step 5 Position the four bolts on the access point into the bracket keyhole slots. Check to be sure that the
access point is properly seated in the slots.(See Figure 9)
Note The access point should be positioned with the LEDs on the bottom to allow viewing from
the ground.
Step 6 Using a 10mm wrench, tighten the four bolts that connect the access point to the bracket to a torque
of 40 in-lbf.
Step 7 Locate the access point to its final position. Tighten the band clamps with the wrench so that the
access point does not slide on the pole. Be sure that the clamps are tight enough that the AP does
not move.
Step 8 Continue with the Grounding the Access Point, page 23.