User Manual
Table Of Contents
- 1 About this Guide
- 2 Introduction to the Access Point
- 3 Unpacking the Access Point
- 4 Radio Configuration
- 5 Becoming Familiar With the Access Point
- 6 AP Pole/Wall Mount
- 7 Preparing the Access Point
- 8 Deploying the Access Point
- 9 In Case of Difficulty
- 10 Declarations of Conformity and Regulatory Information
- Regulatory Domains
- FCC Safety Compliance Statement
- Declaration of Conformity for RF Exposure
- Declaration of Conformity with Regard to the EU Directive 1999/5/EC (R&TTE Directive)
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- VCCI Statement for Japan
- Guidelines for Operating Cisco Access Points in Japan
- Statement 371-Power Cable and AC Adapter
- Industry Canada
- Canadian Compliance Statement
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC & Medical Directive 93/42/EEC
- Declaration of Conformity for RF Exposure
- Administrative Rules for Cisco Access Points in Taiwan
- Operation of Cisco Aironet Access Points in Brazil
- Declaration of Conformity Statements
- 11 Warranty
18
Wall Mounting the Access Point with the Fixed Mounting Kit
The optional fixed mounting kit contains a mounting bracket for wall mounting or pole mounting.
You can use the mounting bracket as a template to mark the positions of the mounting holes for your
installation. You then install the mounting plate, and attach the access point when you are ready.
Table 1 lists the materials you will need to provide in addition to the fixed mounting kit.
Ta b l e 1 Material Needed to Mount Access Point to a Vertical Wall
Caution The mounting surface, attaching screws and optional wall anchors must be able to
support a 50-lb (22.7 kg) static weight.
To mount the access point on a vertical wall, follow these instructions:
Step 1 Use the mounting bracket as a template to mark four screw hole locations on the mounting
surface. See
Figure 8 for the mounting bracket screw hole locations. You can optionally use
the individual mounting holes or the mounting slots.
Materials Required In Kit
Ground lug and screws (provided with access point) Yes
Crimping tool for ground lug, Panduit CT0720 with
CD-720-1 die (http://onlinecatalog.paduit.com)
No
Four M8 or 5/16 in. (31 mm) screws No
Four wall anchors (specified for all material) No
Drill bit for wall anchors No
Electric drill and standard screwdriver No
#6 AWG ground wire No
Shielded outdoor-rated Ethernet (CAT5e or better) cable No
Grounding block No
Grounding rod No
13-mm box-end wrench or socket set No