User Manual
Table Of Contents
- 1 About this Guide
- 2 Introduction to the Access Point
- 3 Unpacking the Access Point
- 4 Radio Configuration
- 5 Becoming Familiar With the Access Point
- 6 AP Pole/Wall Mount
- 7 Preparing the Access Point
- 8 Deploying the Access Point
- 9 In Case of Difficulty
- 10 Declarations of Conformity and Regulatory Information
- Regulatory Domains
- FCC Safety Compliance Statement
- Declaration of Conformity for RF Exposure
- Declaration of Conformity with Regard to the EU Directive 1999/5/EC (R&TTE Directive)
- Manufacturers Federal Communication Commission Declaration of Conformity Statement
- VCCI Statement for Japan
- Guidelines for Operating Cisco Access Points in Japan
- Statement 371-Power Cable and AC Adapter
- Industry Canada
- Canadian Compliance Statement
- European Community, Switzerland, Norway, Iceland, and Liechtenstein
- Declaration of Conformity with regard to the R&TTE Directive 1999/5/EC & Medical Directive 93/42/EEC
- Declaration of Conformity for RF Exposure
- Administrative Rules for Cisco Access Points in Taiwan
- Operation of Cisco Aironet Access Points in Brazil
- Declaration of Conformity Statements
- 11 Warranty
41
Note Regarding LED status colors, it is expected that there will be small variations in color intensity
and hue from unit to unit. This is within the normal range of the LED manufacturer’s
specifications and is not a defect.
Operating
Status
Blinking Amber A software upgrade is in progress
Cycling through Green,
Red and Amber
Discovery/join process is in progress
Rapidly cycling through
Red, Green, Amber and
Off
This status indicates that the Access Point location
command has been invoked.
Blinking Red This status indicates that an Ethernet link is not
operational
Alignment
Mode
Color Signal Level (dBm)
Solid Green > –44
Fast blinking Green –47 to –44
Medium blinking Green –50 to –47
Solid Amber –53 to –50
Fast blinking Amber –57 to –53
Medium blinking Amber –60 to –57
Slow blinking Amber –63 to –60
Slow blinking Red –66 to –63
Medium blinking Red –69 to –66
Fast blinking Red –72 to –69
Solid Red –75 to –72
Off < –75
LED Message
Type
Color Meaning