Installation Guide

2-15
Cisco Aironet 1560 Series Outdoor Access Point Hardware Installation Guide
Chapter 2 Installing the Access Point
Mounting the Access Point
Pole Mounting the Access Point with the AIR-ACC1560-PMK1= Kit
The AIR-ACC1560-PMK1= fixed mounting kit contains a mounting bracket, for both wall-mounting
and pole-mounting, the access point along with the power supply kit. This mounting kit supports metal,
wood or fiberglass poles from 2 to 8 inches in diameter.
Ta b l e 2 - 4 Materials Needed to Mount the AP
To mount the access point onto a vertical pole or streetlight pole, follow these steps:
Step 1 Select a mounting location on the pole to mount the access point. You can attach the access point to a
pole having a diameter of 2 to 8 inches (5.1 to 20.1 cm).
Note If you will be using a streetlight power tap adapter, position the access point within 3 ft (1 m) of
the outdoor light control. An AC/DC adapter needs to be used for street light pole deployments.
Step 2 Hold the bracket up against the pole, and slide the three band straps through the top, middle, and bottom
sets of mounting slots on the mounting bracket (see Figure 2-6).
Step 3 Wrap the band straps around the pole, lock them and then lightly tighten the clamps using a wrench. Only
tighten them enough to keep the bracket from sliding down the pole
Step 4 Screw an M6 bolt into each of the four bolt holes on the back side of the access point. Do not screw the
bolt in all the way. Leave a gap of about 0.13" (3.3mm).
Step 5 Position the four bolts on the access point into the bracket keyhole slots. Check to be sure that the access
point is properly seated in the slots (see Figure 2-6).
Note The access point should be mounted with the status LED on the base facing downwards.
Materials Needed In Kit?
One wall mount bracket Yes
Four M6 x12mm hex head bolts Yes
Four #8-32 screws to mount the power supply Yes
Three stainless steel band clamps (adjustable 2"–5", 51–127
mm)
Yes
Three stainless steel band clamps (adjustable 5"–8", 127–203
mm)
Yes
10 mm box-end wrench No
Outdoor rated shielded ethernet cable No
Ground lug (provided with the access point) Yes
Ground block and rod No
Crimping tool for ground lug, Panduit CT-720 with CD-720-1
die (http://www.panduit.com)
No
#6 AWG ground wire No