Quick Start Quick Start Guide for Cisco 1040 Sensor 1 Overview 2 Preparing to Connect Your Cisco 1040 3 Connecting Your Cisco 1040 4 Using Your Cisco 1040 5 Where to Go Next 6 Related Documentation 7 Technical Specifications 8 Regulatory Compliance and Safety Information for Your Cisco 1040 9 Obtaining Documentation 10 Documentation Feedback 11 Cisco Product Security Overview 12 Product Alerts and Field Notices 13 Obtaining Technical Assistance 14 Obtaining Additional Publications and Inf
1 Overview This guide is designed to help you quickly set up and use your Cisco 1040 Sensor (Cisco 1040). A Cisco 1040 is a shelf-top unit that connects to the network and obtains Power over Ethernet (PoE) through a Cisco Catalyst switch. It is easy to connect your Cisco 1040.
2 Preparing to Connect Your Cisco 1040 This section describes tasks that you must perform the first time you set up your network to support Cisco 1040 operations. If you have not already completed the following tasks, it is advisable to complete them so that your Cisco 1040 becomes fully operational minutes after you connect it.
1 Cisco 1040 Cable Connections—Front Panel 1 2 10/100-1 10/100-2 10/100-1—Fast Ethernet port, standard RJ45 3 for connecting to the network and obtaining inline power. 3 POWER 141283 Figure 1 Status indicator light—See Understanding the Status Indicator Light, page 7. This port supports IEEE 802.3af standard PoE. Note 2 This port does not support Cisco prestandard PoE. 10/100-2—Fast Ethernet port, standard RJ45 — — for connecting to a SPAN or Remote SPAN (RSPAN) destination port.
Cisco 1040 Port Usage This section provides a list of ports used by the Cisco 1040, for your reference. Table 1 Cisco 1040 Port Usage Protocol Port Number Service Name UDP 53 DNS UDP 67 and 68 DHCP UDP 69 TFTP—Cisco 1040 uses TFTP to get a configuration file and binary image file. UDP 5666 Syslog—Cisco 1040 sends syslog messages to Service Monitor. TCP 2000 SCCP—Cisco 1040 uses SCCP to communicate with Service Monitor.
Step 1 Place the Cisco 1040 on top of the appropriate Cisco Catalyst switch. Note The minimum height necessary to install the Cisco 1040 is 5.08 cm (2 in.). The installation of the unit should not restrict the airflow around the device. When operating the unit, ensure that no objects are placed on top of the unit. Step 2 Connect a Category 5 straight-through cable from 10/100-1 (Fast Ethernet port 1) on the Cisco 1040 to a port that supports IEEE 802.3af standard PoE on the Cisco Catalyst switch.
Understanding the Status Indicator Light The status indicator light on the front panel of a Cisco 1040 indicates what the Cisco 1040 is currently doing. The following table lists the conditions that the status indicator light can be in and places the conditions in startup sequence order. Startup Sequence Number Status Indicator Light Cisco 1040 Condition 1 Orange solid Initial state 2 Yellow and flashing Obtained power from the switch and is doing one of the following: 1.
Using the Cisco 1040 Web Interface You can open a web interface to view information stored on a Cisco 1040 as follows. Step 1 In your browser, enter http:// where IP address is the address of your Cisco 1040 and DNS name is the DNS name for the Cisco 1040. For example: http://Cisco-1040-sj The Device Information window displays the following information: • ID—Cisco 1040 ID. • MAC Address—Cisco 1040 MAC address. • Time stamp—Current time on the Cisco 1040.
• Last Updated—The last time that this configuration file was updated on the Service Monitor system. • CDPGlobalRunState—States whether CDP is enabled (true) or disabled (false). • SyslogPort—States the port protocol (UDP) and port number used for sending syslogs to Service Monitor. • SkinnyPort—States the port protocol (TCP) and port number used to communicate with Service Monitor.
6 Related Documentation Note Although every effort has been made to validate the accuracy of the information in the printed and electronic documentation, updates are sometimes necessary. Any changes to the original publications are reflected on Cisco.com, where you will find the most up-to-date documentation. For information about configuring SPAN and RSPAN ports on Cisco Catalyst switches, see the software configuration guide for the appropriate switch model and Cisco IOS version.
Table 2 Related Documentation To learn more about... See this document On the Cisco In the On the Doc. product product On package? CD? Cisco.
Physical and Operating Environment Specifications Specification Value or Range Operating temperature 0° to 40°C (32° to 104°F) Operating relative humidity 10% to 90% (non-condensing) Height 3.8 cm (1.5 in.) Width 24.1 cm (9.5 in.) Depth 20.3 cm (8 in.) Weight .5kg (1.0 lb.) Power 2.
Pin Number Function 7 CTS—Clear to send 8 RTS—Request to send 8 Regulatory Compliance and Safety Information for Your Cisco 1040 Caution If the Cisco 1040 is used in a manner not specified by Cisco, the protection provided in the equipment might be impaired. Caution Inline power circuits provide current through the communication cable. Use the Cisco-provided cable or a minimum 24 AWG communication cable (for example, CAT 5, 24 AWG). Caution The Cisco 1040 has no operator-serviceable parts inside.
Warning Definition—Statement 1071 Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device.
Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Advarsel VIKTIGE SIKKERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten.
Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
Translated Warnings This section contains the following warnings translated into multiple languages: • Statement 1004—Installation Instructions, page 22 • Statement 1001—Work During Lightning Activity, page 23 • Statement 1021—SELV Circuit, page 24 • Statement 1045—Short-circuit Protection, page 27 • Statement 1074—Comply with Local and National Electrical Codes, page 29 • Statement 1040—Product Disposal, page 30 • Statement 19—TN Power Warning, page 34 • Statement 331—Power Supply Installation Warning, pag
• Statement 353—This Product Must be Connected, page 36 • Statement 1005—Circuit Breaker, page 37 • Statement 1019—Main Disconnecting Device, page 39 Statement 1004—Installation Instructions Warning Waarschuwing Varoitus Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit. Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Statement 1001—Work During Lightning Activity Warning Waarschuwing Varoitus Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001 Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen. Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla. Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
¡Advertencia! Varning! No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera. Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. Statement 1021—SELV Circuit Warning Waarschuwing 24 To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits.
Varoitus Jotta vältyt sähköiskulta, älä kytke pienjännitteisiä SELV-suojapiirejä puhelinverkkojännitettä (TNV) käyttäviin virtapiireihin. LAN-portit sisältävät SELV-piirejä ja WAN-portit puhelinverkkojännitettä käyttäviä piirejä. Osa sekä LAN- että WAN-porteista käyttää RJ-45-liittimiä. Ole varovainen kytkiessäsi kaapeleita.
¡Advertencia! Para evitar la sacudida eléctrica, no conectar circuitos de seguridad de voltaje muy bajo (safety extra-low voltage = SELV) con circuitos de voltaje de red telefónica (telephone network voltage = TNV). Los puertos de redes de área local (local area network = LAN) contienen circuitos SELV, y los puertos de redes de área extendida (wide area network = WAN) contienen circuitos TNV. En algunos casos, tanto los puertos LAN como los WAN usan conectores RJ-45.
Statement 1045—Short-circuit Protection 27
Statement 1074—Comply with Local and National Electrical Codes Warning Waarschuwing Installation of the equipment must comply with local and national electrical codes. Statement 1074 Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften. Varoitus Laitteisto tulee asentaa paikallisten ja kansallisten sähkömääräysten mukaisesti. Attention L'équipement doit être installé conformément aux normes électriques nationales et locales.
Statement 1040—Product Disposal Warning Waarschuwing Varoitus Het uiteindelijke wegruimen van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. Tämä tuote on hävitettävä kansallisten lakien ja määräysten mukaisesti. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
Varning! Vid deponering hanteras produkten enligt gällande lagar och bestämmelser. Aviso O descarte definitivo deste produto deve estar de acordo com todas as leis e regulamentações nacionais. Advarsel Endelig bortskaffelse af dette produkt skal ske i henhold til gældende love og regler.
Statement 353—This Product Must be Connected Warning Waarschuwing Varoitus Attention 32 This product must be connected to a power-over-ethernet (PoE) IEEE 802.3af compliant power source or an IEC60950 compliant limited power source. Statement 353 Dit product moet worden verbonden met een stroomvoorziening die compatibel is met PoE (power-over-ethernet) IEEE 802.3af of een beperkte stroomvoorziening die compatibel is met IEC60950. Tämä tuote on liitettävä PoE (power-over-ethernet) IEEE 802.
Warnung Dieses Produkt muss entweder an eine Stromquelle angeschlossen sein, die mit dem IEEE 802.3af-Standard Power-over-Ethernet (PoE) kompatibel ist oder an eine Stromquelle für geringe Leistungen, die IEC60950-kompatibel ist. Avvertenza Questo prodotto deve essere connesso a una fonte di alimentazione di tipo PoE (power-over-ethernet) conforme a IEEE 802.3af o a una fonte di alimentazione conforme a IEC60950. Advarsel Dette produktet må være koblet til en Power-over-Ethernet (PoE) IEEE 802.
When using an AC/DC power supply, the following warnings apply: • Statement 19—TN Power Warning, page 34 • Statement 331—Power Supply Installation Warning, page 35 • Statement 353—This Product Must be Connected, page 36 • Statement 1005—Circuit Breaker, page 37 • Statement 1019—Main Disconnecting Device, page 39 Statement 19—TN Power Warning Warning Waarschuwing Varoitus Het apparaat is ontworpen om te functioneren met TN energiesystemen.
¡Advertencia! Varning! El equipo está diseñado para trabajar con sistemas de alimentación tipo TN. Enheten är konstruerad för användning tillsammans med elkraftssystem av TN-typ. Statement 331—Power Supply Installation Warning Warning Waarschuwing Varoitus The power supply must be placed indoors. Statement 331 De stroomtoevoer moet binnen worden geplaatst. Tehonlähde on sijoitettava sisätiloihin. Attention Le bloc d’alimentation électrique doit être placé à l’intérieur.
¡Advertencia! Varning! El suministro de energía debe estar ubicado en un lugar cubierto y no al aire libre. Strömkällan måste vara placerad inomhus.
Statement 1005—Circuit Breaker Warning Waarschuwing This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 120 VAC, 15A (U.S./CAN); 240 VAC, 10A (INTERNATIONAL) Statement 1005 Dit product is afhankelijk van de installatie van het gebouw voor beveiliging tegen kortsluiting (overstroom). Controleer of de beschermingsinrichting niet meer dan: 120 VAC, 15A (U.S./CAN); 240 VAC, 10A (INTERNATIONAL) is.
Aviso ¡Advertencia! Varning! Este produto depende das instalações existentes para proteção contra curto-circuito (sobrecarga). Assegure-se de que o fusível ou disjuntor não seja superior a: 120 VAC, 15A (U.S./CAN); 240 VAC, 10A (INTERNATIONAL) Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio. Asegúrese de que el dispositivo de protección no sea superior a: 120 VAC, 15A (U.S.
Statement 1019—Main Disconnecting Device Warning The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. Statement 1019 Waarschuwing De combinatie van de stekker en het elektrisch contactpunt moet te allen tijde toegankelijk zijn omdat deze het hoofdmechanisme vormt voor verbreking van de aansluiting. Varoitus Pistoke/liitinkohta toimii pääkatkaisumekanismina. Pääsy siihen on pidettävä aina esteettömänä.
European Directives Statement 275—Declaration of Conformity with Regard to the Directives 73/23/EEC and 89/336/EEC as amended by Directive 93/68/EEC For specifics about which standards have been applied, refer to the Declaration of Conformity. English: Dansk: 40 This equipment is in compliance with the essential requirements and other provisions of Directives 73/23/EEC and 89/336/EEC as amended by Directive 93/68/EEC.
Français: Cet appareil remplit les principales conditions requises et autres dispositions des Directives 73/23/EEC et 89/336/EEC, modifiées par la Directive 93/68/EEC. Íslenska: Þessir búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipana 73/23/EBE og 89/336/EBE, með breytingum skv. tilskipun 93/68/EBE. Italiano: Questa apparecchiatura è conforme ai requisiti essenziali e altre disposizioni delle Direttive 73/23/EEC e 89/336/EEC modificate con la Direttiva 93/68/EEC.
Regulatory Standards Compliance This section includes all regulatory, safety, and electromagnetic compatibility (EMC) standards. The Cisco 1040 is in compliance with national and international standards as described in Table 3. Table 3 Regulatory Standards Compliance Specification Description Regulatory Compliance Products with the CE Marking indicate compliance with the 89/336/EEC and 73/23/EEC directives, which include the safety and EMC standards listed. Safety UL 60950 CAN/CSA-C22.2 No.
EMC Environmental Conditions for Products Installed in the European Union This section applies to products to be installed in the European Union. The equipment is intended to operate under the following environmental conditions with respect to EMC: • A separate defined location under user’s control. • Earthing and bonding shall meet the requirements of ETS 300 253 or CCITT K27. • AC power distribution shall be one of the following types, where applicable: TN-S and TN-C as defined in IEC 364-3.
Class B Notice for Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Statement 295—Class B Warning for Korea Warning This is a Class B Device and is registered for EMC requirements for residential use. This device can be used not only in residential areas but in all other areas.
9 Obtaining Documentation Cisco documentation and additional literature are available on Cisco.com. This section explains the product documentation resources that Cisco offers. Cisco.com You can access the most current Cisco documentation at this URL: http://www.cisco.com/techsupport You can access the Cisco website at this URL: http://www.cisco.com You can access international Cisco websites at this URL: http://www.cisco.com/public/countries_languages.
10 Documentation Feedback You can provide feedback about Cisco technical documentation on the Cisco Support site area by entering your comments in the feedback form available in every online document. 11 Cisco Product Security Overview Cisco provides a free online Security Vulnerability Policy portal at this URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.
Tip We encourage you to use Pretty Good Privacy (PGP) or a compatible product (for example, GnuPG) to encrypt any sensitive information that you send to Cisco. PSIRT can work with information that has been encrypted with PGP versions 2.x through 9.x. Never use a revoked encryption key or an expired encryption key. The correct public key to use in your correspondence with PSIRT is the one linked in the Contact Summary section of the Security Vulnerability Policy page at this URL: http://www.cisco.
Cisco Support Website The Cisco Support website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day at this URL: http://www.cisco.com/en/US/support/index.html Access to all tools on the Cisco Support website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL: http://tools.cisco.
Submitting a Service Request Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool provides recommended solutions. If your issue is not resolved using the recommended resources, your service request is assigned to a Cisco engineer.
14 Obtaining Additional Publications and Information Information about Cisco products, technologies, and network solutions is available from various online and printed sources. • The Cisco Online Subscription Center is the website where you can sign up for a variety of Cisco e-mail newsletters and other communications. Create a profile and then select the subscriptions that you would like to receive. To visit the Cisco Online Subscription Center, go to this URL: http://www.cisco.
• “What’s New in Cisco Documentation” is an online publication that provides information about the latest documentation releases for Cisco products. Updated monthly, this online publication is organized by product category to direct you quickly to the documentation for your products. You can view the latest release of “What’s New in Cisco Documentation” at this URL: http://www.cisco.com/univercd/cc/td/doc/abtunicd/136957.htm • World-class networking training is available from Cisco.
Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 European Headquarters Cisco Systems International BV Haarlerbergpark Haarlerbergweg 13-19 1101 CH Amsterdam The Netherlands www-europe.cisco.com Tel: 31 0 20 357 1000 Fax: 31 0 20 357 1100 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.