Installation Manual Part 2
Table Of Contents
PRELIMINARY
6-10
BWX 8415 Basestation Installation and Commissioning Guide
OL-19519-01
Chapter 6 Installation
6.3.4 Mounting the BWX 8415 Basestation
Warning
In order to comply with radio frequency (RF) exposure limits, the antennas for this product should be
positioned no less than 6.56 ft (2 m) from your body or nearby persons.
Statement 339
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
6.3.4.1 Mounting the BWX 8415 on a Wall
When installing the BWX 8415 on an outdoor wall, ensure that the wall and mounting hardware (anchor
bolts) chosen to mount the BS are capable of supporting both the static weight of the BS and the lateral
load, resulting from wind loading and that the installation adheres to all local building and safety codes.
Note The following specifications should be helpful in planning the wall mounted installation:
Dimensions: 2.3 & 2.5 GHz - 62 X 20 X 12 in (158 X 50 X 30 cm)
3.5 GHz - 62 X 14.5 X 12 in (158 X 37 X 30 cm)
Weight: 110 lbs. (50 kg) w/o filters [does not include the external cable strain relief]
Wind Loading: 170 lbs. with 100 mile/h lateral thrust (77 kg with 161 km/h lateral thrust)
Ice Loading: The BS can operate with up to .75 in (1.9 cm) thick buildup of ice without sustaining
damage.
6.3.4.2 Mounting the BWX 8415 on a Pole
When installing the BWX 8415 on a pole, keep in mind that the mounting bracket supports metal, wood,
or fiberglass poles from 3 - 4.5 inches (7.6 - 11.4 cm) in diameter.
Figure 6-9 illustrates the mounting
bracket.