Installation Manual Part 3

PRELIMINARY
7-41
BWX 8415 Basestation Installation and Commissioning Guide
OL-19519-01
Chapter 7 Commissioning
7.7.3 Calibration Procedure
To determine if a problem exists, use the following information:
At the BS console, look at the cal error message. The calibration should pass without any errors.
Look at the Transmit Gain values. They should be relatively close to each other (values: 1 - 64).
Find the median Transmit Gain value. The median is the value that falls in the middle of the
lowest to highest values. Example: If you ordered the values 9, 8, 8, 7, 7, 6, 5, 4, 3, 3, 3, 2, 1,
1….the median would be 5 because 5 falls midway from the top or bottom of the ranked values.
Compare all the other Transmit Gain values to the median value. All Transmit Gain values
should be within a plus or minus range of 6 units from the median. Therefore, if the median is
50, values from 44 to 56 would be acceptable.
Look at the Receive Gain values. (values: 115 – 255)
Find the median Receive Gain value.
Compare all the Receive Gain values to the median value. All Receive Gain values should be
within a plus or minus range of 8 units from the median.
Criteria:
Transmit Gain Words +/- 6 from the median value
Receive Gain Words +/- 8 from the median value
If this is a new installation (or a problem is found), repeat the calibration procedure (Steps 4-8). This
will be the second of three calibrations you will perform. Click on the Configure button for this BS, and
a new window appears (
Figure 7-47). The main “Show” window still shows the results of the first
calibration. The Configuration window shows the values corresponding to the second calibration.
Figure 7-47 Second Calibration (if needed)