Installation Manual Part 4

PRELIMINARY
7-28
BWX 8415 Basestation Installation and Commissioning Guide
OL-19519-01
Chapter 7 Commissioning
7.6 Power Up and Provision the BWX 8415 Basestation
7.6 Power Up and Provision the BWX 8415 Basestation
Reference: BWX EMS Alarm Resolution Reference Manual
7.6.1 Prerequisites
The EMS must be up and IP-reachable from the BS
The BWG must be running and configured
The BS must have been already added to and configured in the EMS
All equipment in the system must be IP-reachable
If a laptop with a Test EMS is being used (recommended procedure during commissioning), connect
this laptop to the BS via a Telnet session
Note The Telnet session will not be established until after the BS has booted up.
Make sure the ‘Test’ EMS server is running on a laptop
Open a terminal emulation session using one of the following programs:
Tera Term Pro
HyperTerm
Other terminal emulation programs
Verify the serial port settings
Figure 7-37 Serial Port Settings